Inputs
This menu allows configuration of the alarm settings, refer to 'Installing the Unit' for hardware installation
guidance.
Number
Enabled
N_O (Normally Open Contact)
Note:
If EOL alarms are to be used, this option should not be selected i.e. leave set as
Normally Closed.
EOL
64
This identifies which input is being configured. The unit supports 2
on-board alarms.
Each input must be enabled to function. If the input is not enabled and
an alarm is received, the unit will not acknowledge the alarm.
N_O indicates the non-alarm state of the input. Tick the N_O
checkbox to set the corresponding input to Normally Open. The alarm
will then trigger when the input is closed (shorted). If left as Normally
Closed (the default setting), the alarm will trigger when the input is
opened.
The End Of Line (EOL) option enables the inputs to detect any
changes in the electronic input resistance. A change outside the
expected values will result in a Tamper Alarm (short circuit or open
circuit) being detected and the system switching to alarm mode.