No.
Component
45
Separation board
40., 41., 48., 49., 54.,
55.
46
Guide water
40., 41., 48., 49.,
54. to 56.
47
Supply water pipe
assembly
40., 41., 48., 49., 54.,
55., 57.
<VNK type only>
48
Quick fastener
40., 41., 48., 49., 58.
<VNK type only>
Procedure
55. Use pliers or the like to push inward the sensor
assembly 1 fixed on the separation board.
Remove the three truss head tapping screws (M4 ×
10) that fix the separation board.
Push the lower part of the separation board deep to
pull it toward you.
56. Remove the truss head tapping screw (M4 × 10)
that fixes the guide water.
Pull the guide water up and then toward you.
57. Use a spanner (17) to loosen the flare nut that fixes
the supply water pipe assembly to remove the
assembly.
58. Pull down the quick fastener in the direction against
the opening to remove the quick fastener.
Tapping screws (M4 × 10)
Tapping screws (M4 × 10) Guide water
195
Note
Sensor assembly 1
Flair nut
Opening
Quick