No.
Component
30
Inspection cover 2
40.
31
Spacer
40., 41.
<VNK type only>
32
Humidifying element
40. to 42.
<VNK type only>
33
Humidifying block
assembly
40. to 43.
<VNK500 type only>
Procedure
40. Loosen the six screws and then remove the
inspection cover 2.
* The inspection cover and screws are a set.
41. Hold the handle of the spacer, and then pull it
toward you.
42. Slide the hose band to remove the supply water
hose. Pull out the humidifying element toward you.
(1 element for VNK500 type)
(2 elements for VNK800 / 1000 types)
43. Pull out the humidifying block assembly toward
you.
Hose band
191
Note
Screws
Handle
Humidifying element
Supply
water hose
Humidifying block
assembly