5. OEMSE Commands

5.15. OEMSEPing

Command
OEMSEPing
Description
This command will send an ICMP ping request to the specified IPv4 address.
Syntax
OEMSEPing [common_options] -OEMSEparams IPAddress="< value >" [SM-CLP-target]
Options
[common_options]
Parameter
Description
Optional input that indicates the SM-CLP target group for the given command. This
SM-CLP-target
overrides the current group. ".." indcates parent group. "/" indicates root group.
-
takes in additional parameters as arguments as listed below in the Parameters table
OEMSEParams
of this section. The parameters has to be entered in a key=value format.
Required Parameters
Parameter
Data
Name
Type
IPAddress
ipaddress
Optional Parameters
None
Possible Error Messages
Common Error Messages
Invalid value,
Min
Max
Default
Description
The IPv4 address to which the ICMP ping
0
0
0.0.0.0
request will be sent.
5.15. OEMSEPing