Design Guide - Stainless Steel Installation

THE INSTALLATION SPACE

Finished Width
2-5/16"
10"
84-1/2" max
24" Cutout Depth
Finished
Water Supply
Opening
3-1/2"
5"
10"
Water And Electrical Locations
Electrical and water supply must be located as shown.
The Cutout Depth Must Be 24"
The refrigerator will project forward, slightly beyond
adjacent cabinetry, depending on your installation.
Allow minimum 1/8" air gap between case back & wall.
Cutout depth beneath a soffit:
When installed beneath a soffit, the soffit cannot exceed
the 24" installation depth shown. The top case trim
overlaps the bottom of the soffit.
Additional Specifications
• A 115 volt 60Hz., 15 or 20 amp power supply is required.
An individual properly grounded branch circuit or circuit
breaker is recommended. Install
a properly grounded 3-prong electrical receptacle
recessed into the back wall. Electrical must be located on
rear wall as shown.
NOTE: GFI (ground fault interrupter) is not recommended.
• Water line can enter the opening through the floor
or back wall. Route GE SmartConnect
copper tubing between the cold water line and the water
connection location. The tubing should be
long enough to extend to the front of the refrigerator.
Installation of an easily accessible shut-off valve in the
water line is required.
35-1/2"
Wall View
6"
Electrical
Area
75" From
Floor to Bottom
of Electrical Area
3-1/2"
5"
10"
3-1/2"
kit or 1/4" O.D.

DIMENSIONS AND CLEARANCES

35"
Case Width
*83-1/2"
at
Rear
Depth Including Handles:
27-3/4" Stainless Steel Models
28-11/16" Professional Style Models
Product Clearances
These refrigerators are equipped with a 3-position door
stop. The factory set 115° door swing can be adjusted to
90° if clearance to adjacent cabinets or walls is restricted.
Allow 25" minimum clearance for
a full 130° door swing. Allow 15"
for pan removal.
For a 90° door swing, allow
4" min. clearance to a wall,
for framed and stainless steel
models. Allow 5" min. clearance
for professional style models. If
the 90° door stop position is used,
pan access is maintained, but pan
removal is restricted.
See illustration on page 39 to determine door swing
interaction with adjacent cabinets or countertops.
37
25-3/4"
Case Depth
* Shipping height. The
refrigerator can be
adjusted to fit into a
cutout that is 84-1/2
*84" From
Floor to
max. height. Note that
Top Frame
the top case trim at
the front is 1/2
and will overlap upper
cabinetry or soffit. Use
leveling legs and wheels
for a maximum 1
adjustment.
36" Frame to
Frame Width
115° Door Swing
"
"
higher
"
height