THE INSTALLATION SPACE

Finished Width
4-5/16"
10"
26-3/16" Cutout
85"
Finished
Opening
Water Supply
3-1/2"
7"
3-1/2"
Water And Electrical Locations
Electrical and water supply must be located as shown.
The Cutout Depth Must Be 26-3/16"
Wooden cleats are required for flush installation. See Side
Cleats on page 27.
Cutout depth beneath a soffit:
When installed beneath a soffit, the soffit cannot exceed
the 26-3/16" installation depth shown. The top case trim
overlaps the bottom of the soffit.
Additional Specifications
• A 115 volt 60Hz., 15 or 20 amp power supply is required.
An individual properly grounded branch circuit or circuit
breaker is recommended. Install a properly grounded
3-prong electrical receptacle recessed into the back wall.
Electrical must be located on rear wall as shown.
NOTE: GFI (ground fault interrupter) is not recommended.
• Water line can enter the opening through the floor or back
wall. Route GE SmartConnect
between the cold water line and the water connection
location. The tubing should be long enough to extend to the
front of the refrigerator. Installation of an easily accessible
shut-off valve in the water line is required.

CUSTOM HANDLE DESIGN GUIDE

Custom handles must be used for flush installation. For
custom handle installation, counterbore holes in rear of
decorative panels must ensure 1/2" material thickness
remains for handle support.
NOTE: The counterbore must not exceed 1" in diameter.
1/2"
1/4"
3/4"
Design Guide - Flush Installation
39"
Wall View
6"
Electrical
Area
75-1/2" From
Depth
Floor to Bottom
of Electrical Area
3-1/2"
7"
3-1/2"
3-1/2"
kit or 1/4" O.D. copper tubing

DIMENSIONS AND CLEARANCES

35"
Case Width
*83-1/2"
at
Rear
Depth Including Handles 26-7/8"
Product Clearances
These refrigerators are equipped with a 3-position door
stop. The factory set 115° door swing can be adjusted to
90° if clearance to adjacent cabinets or walls is restricted.
20-5/8"
Behind
90° Door Swing
Frame
38-3/4"
90°
*Min. Distance to Wall: 4"
For a 90 degree door swing, allow 4" min. clearance to
wall. If the 90 degree door stop position is used, pan
access is maintained, but pan removal is restricted
Minimum distance on Fresh Food
Door from handle side edge to
handle center should be 2-1/2"
as shown.
Minimum distance on Freezer
Door from top edge to handle
center on the freezer drawer
should be 1-1/2" as shown.
7/8"
0.85"
1/2"
21
25-3/8"
Framed Models
* Shipping height. The
refrigerator can be
adjusted to fit into a
*84" From
cutout that is 85
Floor to
height. Use leveling
Top Frame
legs and wheels for a
maximum 1
adjustment.
36" Frame to
Frame Width
115° Door Swing
2-1/2"
1-1/2"
"
max.
"