6-6

Power Supply

The SuperServer 6027AX-72RF/TRF-HFT1/HFT2/HFT3 has a 1280 watt redundant
power supply consisting of two power modules. Each power supply module has an
auto-switching capability, which enables it to automatically sense and operate at a
100V - 240V input voltage.

Power Supply Failure

If either of the two power supply modules fail, the other module will take the full
load and allow the system to continue operation without interruption. The PWR Fail
LED will illuminate and remain on until the failed unit has been replaced. Replace-
ment units can be ordered directly from Supermicro. The power supply units have
a hot-swap capability, meaning you can replace the failed unit without powering
down the system.
Removing the Power Supply
1. First unplug the AC power cord from the failed power supply module.
2. Depress the release tab on the power supply module as illustrated.
3. Use the handle to pull the module straight out of the chassis.
Installing a New Power Supply
1. Replace the failed hot-swap unit with another identical power supply unit.
2. Push the new power supply unit into the power bay until you hear a click.
3. Plug the AC power cord back into the unit and power up the server..