Ethernet Troubleshooting

„ When communication is not possible
Cause
The power is not on.
The LAN cable is not
connected correctly.
The LAN cable is broken.
Network system error
The IP address is not set
correctly.
The subnet mask is not
set correctly.
The routing table is not
set correctly.
The connections exceed
the maximum number
of device connections
usable at the same time.
(Max. 20 users)
The set IP address is
being used on another
device (multiple use of an
address).
The set IP address was
previously used on
another device.
For settings using the
DNS server, the DNS
server is not set up, or the
IP address setting of the
DNS server on the Printer
is incorrect.
Check
Is the power switch turned on?
z
Is the power cord connected
z
correctly?
Is the cable connected correctly to the
jack?
Can a connection be made to
z
another host device or peripheral
device, such as a printer?
Is the ping command to the device
z
enabled?
Check that LP-2050 operation is being
performed with the ping command
from the host device.
Are the device settings and the IP
address received from the system
administrator the same?
Are the device settings and the
subnet mask received from the system
administrator the same?
Are the device settings and the IP
z
router address received from the
system administrator the same?
Is the address of the network system
z
at the connection destination
correct?
Are devices connected at the same
time on multiple host devices?
Check with the system administrator.
Check with the system administrator.
Contact and check with the system
administrator.
LP-2050/LP-2050-MF User's Manual for Basic Printer Operation
Action
Turn on the power switch.
z
Connect the power cord correctly.
z
Connect fully and correctly.
z
If connected, remove and insert
z
again.
Use another LAN cable.
Contact the system administrator.
Set the correct IP address.
Set the correct subnet mask.
Set the correct router IP address.
z
Set the correct connection
z
destination network address. (If
unknown, set 000.000.000.000 and
the default router value.)
Adjust the number of users operating
at the same time.
Use the correct IP address.
The address of the original device is
cached on the host device or a relay
device such as a switch. Clear the
corresponding cache table.
Contact the system administrator.