Power Supply Specifications; Cooling Module Specifications - Rorke Data Galaxy A16F-R2422 Installation And Hardware Manual

Fc-4g to sata-ii raid subsystem redundant controller
Table of Contents

Advertisement

Galaxy A16F-R2422 Installation and Hardware Reference Manual
A.4.

Power Supply Specifications

Specification
Nominal Power
DC Output
Input Frequency
AC Input
Power Factor
Correction
Hold-up Time
2
I
C
Over-temperature
Protection
Cooling Fans
Temperature
Humidity
Altitude
Acoustic Noise
A.5.

Cooling Module Specifications

Specification
Max. Air Flow (each
module)
Input Power
Input Current
Rated Voltage
Acoustic Noise
Temperature
A-4
460W
12.0V: 32A
5.0V: 32A
3.3V: 30A
47 to 63Hz
100VAC @ 10A – 240VAC @ 5A with PFC
Yes
At least 16ms at 115/230VAC full load after a loss of
AC input
Through backplane to RAID controller
Lost cooling or excessive ambient temperature
Two fans for each unit (inside PSU)
Operating: 0°C to 50°C (32°F to 122°F)
Storage: -40°C to 70°C (-40°F to 158°F)
Operating: 20% to 90% non-condensing
Non-operating: 5% to 95% non-condensing
Operating: 0 to- 10,000 ft
Non-operating: 0 to 40,000 ft
115V input, full load
of +5V; 0.5A of +12V
High speed: 31.8 CFM
Low speed: 20.1 CFM
9W max.
0.89A max.
DC 12V
High speed: 55dB max.
Low speed: 44dB max.
Operating: -10 to +60ºC
Storage: -20 to +70ºC
50 dB max.
Specifications

Advertisement

Table of Contents
loading

Table of Contents