Step 6. Hold the MUX kit in place and turn the drive tray over. Insert the
Only use the screws provided in the MUX kit package. The screws size
should be 6#32*4mm. Using an unmatched screw could result in hard
drive malfunction.
Step 7. Install the hard drive to the drive tray. See Section 2.7.2.
Step 8. Install the drive tray with the hard drive to the chassis. See Section
5-24
See Figure 5-37. Make sure that the Fibre connector is facing the
back of the drive tray. The Fibre connector will connect to the
backplane board in the subsystem.
Figure 5-37: Screw Locations on an Empty Drive Tray
two (2) retention screws from the bottom of the drive tray. These
screws will firmly secure the MUX kit to the drive tray and facilitate
the installation of the appropriate drive. (See Figure 5-38)
Figure 5-38: Fastening the MUX Kit Screws
WARNING!
2.8.
Subsystem Maintenance