Components; Normalized Airflow - Rorke Data Galaxy A16F-R2422 Installation And Hardware Manual

Fc-4g to sata-ii raid subsystem redundant controller
Table of Contents

Advertisement

Galaxy A16F-R2422 Installation and Hardware Reference Manual
without affecting the operational integrity of the subsystem. These
components should only be removed from the subsystem when they are
being replaced. At no other time should these components be removed from
the subsystem.
1.4.2

Components

The following components are hot-swappable:
Controller modules (in dual-active mode)
Host connection modules
PSUs
Cooling modules
BBUs
Hard drives
Instructions on how to replace these hot-swappable components are given
in Chapter 5.
1.4.3

Normalized Airflow

Proper subsystem cooling is referred to as "normalized" airflow.
Normalized airflow ensures the sufficient cooling of the subsystem and is
only attained when all components are properly installed. Therefore, a failed
component should only be hot-swapped when a replacement is available. If
a failed component is removed but not replaced, permanent damage to the
subsystem can result.
1-16
NOTE:
Introduction