Replacing A Faulty Psu Module; Psu Module Overview - Rorke Data Galaxy A16F-R2422 Installation And Hardware Manual

Fc-4g to sata-ii raid subsystem redundant controller
Table of Contents

Advertisement

Galaxy A16F-R2422 Installation and Hardware Reference Manual
Step 7. Fasten the retention screws on the host connection module rear
Step 8. Re-insert the SFP transceiver(s) that were previously removed.

5.6 Replacing a Faulty PSU Module

5.6.1 PSU Module Overview

Two (2) redundant PSU modules: The A16F-R2422 is preinstalled
with two (2) 460W, fully redundant, hot-swappable PSU modules.
These modules are located at the rear of the subsystem.
PSU bracket: Each PSU module is permanently mounted in a two-level
steel bracket, creating a single unit. The PSU is located in the upper
level and a removable cooling module is mounted in the lower level.
When removing the PSU from the subsystem, the cooling module is
also being removed.
PSU printing mark: Before you insert a new PSU, be sure that it has
the same printing mark on its handle as that shown on the handle of a
remaining PSU. Double-check to avoid mixing a PSU of previous
Galaxy series. (See Figure 5-20)
5-14
panel to secure the module to the chassis. (See Figure 5-19)
Figure 5-19: Fasten the retention screws