Default Threshold Values; Failed Devices - Rorke Data Galaxy A16F-R2422 Installation And Hardware Manual

Fc-4g to sata-ii raid subsystem redundant controller
Table of Contents

Advertisement

Galaxy A16F-R2422 Installation and Hardware Reference Manual

3.3.1 Default Threshold Values

The threshold values listed below are used to trigger a warning event and
sound the alarm. A different value set is reserved for triggering the
cooling fans to operate at a high rotation speed. The fan speed value set
is not user-configurable.
Table 3-7 shows the default threshold values for the A16F-R2422
subsystem. If any of these values are surpassed, the alarm will sound:
+3.3V
+5V
+12V
CPU Temperature
Board Temperature
Enclosure Ambient
Temperature
The thresholds in Table 3-7 are the default threshold values. To change
these pre-set values, please refer to the Fibre to SATA RAID Subsystem
Operation Manual that came with your system. The values set for the
subsystem's ambient temperature are pre-configured before shipping and
cannot be changed.

3.3.2 Failed Devices

If any of the following devices fail, the audible alarm will be triggered:
3-10
NOTE:
Upper Threshold
+13.2V
Table 3-7: Default Threshold Values
RAID controller modules
Cooling modules
PSU modules
BBU
Hard drives
Lower Threshold
+3.6V
+2.9V
+5.5V
+4.5V
+10.8V
90ºC
80ºC
40ºC
Subsystem Monitoring
5ºC
5ºC
0ºC