5.2.3 Replacing the Controller Module

If the controller module itself has failed, it must be replaced. To replace a
failed controller module:
Step 1. Remove the controller module from the subsystem (see Section
Step 2. Install the DIMM module onto the new controller module; making
Step 3. Install the controller module. Make sure the levers at the back of
Step 4. Reposition the controller module. Once fully inserted, lift up the
Subsystem Maintenance
5.2.2.) If the DIMM module is undamaged, it can be removed and
reinstalled on the new controller module. For instructions on
removing and installing a DIMM module, please see Section 5.3.
sure that the memory module is securely in place. (See Section 5.3)
the controller module are down. Align the controller module with
the controller module bay at the rear of the subsystem. Gently slide
the controller module in. (See Figure 5-4)
Figure 5-4: Installing the Controller Module
levers at the back of the controller module. This will set the
controller module in the correct position. (See Figure 5-5)
Figure 5-5: Lifting the Controller Module Latches Upward
Chapter 5: Subsystem Maintenance
5-5