Power Supply Specifications - Rorke Data GX4L-2240S2-12S6 Installation And Hardware Reference Manual

Galaxy hdx4 12 bay raid
Table of Contents

Advertisement

Galaxy Raid GHDX4 SAS<>SAS/SATA 12Bay Installation / Hardware Reference Manual
Architecture
Specification
CPU
Host Channel Chip
Controllers
DIMM Slot
ASIC
Flash ROM
Hardware XOR
Real-time Clock
A.3

Power Supply Specifications

Specification
Nominal Power
DC Output
Input Frequency
AC Input
Power Factor
Correction
Hold-up Time
Over-temperature
Protection
Cooling Fans
A-4
2x RISC-based CPUs
PMC chipsets
For one 240-pin DDRII SDRAM module
ASIC667 64-bit chipset
64Mbit (8MB)
Yes
For event messages with time record and task
scheduling
350W with active PFC
12.0V: 25A (Max.)
5.0V: 25A (Max.)
3.3V: 20A (Max.)
47 to 63Hz
100VAC @ 6A to 240VAC @ 3A with PFC
Yes
At least 16ms at 115/230VAC full load after a loss of
AC input
Auto shutdown when lost cooling or exceeded
ambient temperature; over-voltage protection is also
available.
Two fans specific for PSU.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gx4l-2240r2-12s6

Table of Contents