Default Threshold Values; Failed Devices - Rorke Data Galaxy Raid GALHDX-7370S-8U4D Installation And Hardware Reference Manual

8 bay scsi u320 to sata-ii raid subsystem
Table of Contents

Advertisement

3.3.1 Default Threshold Values

The threshold values listed below are used to trigger a warning event and sound
the alarm. A different value set is reserved for triggering the cooling fans to
operate at a high rotation speed. The fan speed value set is not user-configurable.
Table 3-8 shows the default threshold values for the subsystem. If any of these values
are surpassed the alarm will sound:
+3.3V
+5V
+12V
CPU Temperature
Board Temperature
Enclosure
Temperature
The controller self-monitoring thresholds in Table 3-8 are the default threshold
values. To change these pre-set values, please refer to the Generic Operation
Manual that came with your system. The values set for the subsystem's ambient
temperature are pre-configured before shipping and cannot be changed.

3.3.2 Failed Devices

The audible alarm will be triggered if any of the following devices fail:
If the temperature exceeds a preset threshold, the BBU charger circuits will stop
charging. You will then receive a message that says "Thermal Shutdown/Enter
Sleep Mode." When the temperature falls back within normal range, the battery
will resume charging.
Audible Alarm
NOTE:
Upper Threshold
+3.6V
+5.5V
+13.2V
90ºC
80ºC
Ambient
40ºC
Table 3-8: Default Threshold Values
Cooling fan modules
PSU modules
BBU modules
Hard drives
Components on the RAID controller
NOTE:
Chapter 3: Monitoring
Lower Threshold
+2.9V
+4.5V
+10.8V
5ºC
5ºC
0ºC
3-9