6 Electronic control panel

6.1 General description

The control panel is powered by 230V on the L-N terminals, with a 50/60 Hz frequency.
The command devices and accessories run on 24V. Moreover, the total accessories cannot run on more than 40W.
The panel controls a service light to light up the service area; at each opening it lights up for 2 minutes and 30 seconds.
The V0670 card may be connected to operate the automation kit with emergency batteries (see the technical documentation attached).
The card automatically controls the following functions:
1) amperometric detection of obstructions during opening, closing and during slow down phases (with adjustable sensitivity);
2) automatic closing (adjustable);
3) working cycle (80");
4) open-stop-close-stop command
5) reopening dueing the closing phase of the photocells.
Protection
Motor
Circuit board (line)
Accessories
Command devices (control unit)
Service
Detail of the amperometric detection of obstructions:
in the opening phase: invert the direction of
movement until completely closed;
in the closing phase: invert the direction of movement until
completely opened;
Warning! After three, consecutive inverted cycles,
the door will stay open excluding automatic closing
function: to close the door, use the remote control or a
command button.
FUSES
Fuse type
7,5A
1,6A
3,15A
315mA
LIGHTS
E14 24V 25W