5.3 Cable list and minimum thickness
Connections
230V power supply
Flashing lamp
Photocell transmitters
Photocell receivers
24V power supply to accessories
Control and safety devices
Antenna connection
N.B.: if the cable length differs from that specified in the table, then you must determine the proper cable diameter in the basis of the actual
power draw by the connected devices and depending on the standards specified in CEI EN 60204-1.
For connections that require several, sequential loads, the sizes given on the table must be re-evaluated based on actual power draw and
distances.
When connecting products other than those mentioned in this manual please see the documents provided with the products themselves.
7
8
6
9
5.4 Applicative examples
SECTIONAL DOOR
COUNTERWEIGHTED PARTIALLY RETRACTABLE SWING OUT
OVERHEAD DOOR
Type of cable
Length of cable 1 < 10 m
3G x 1,5 mm
2 x 0,5 mm
FROR CEI 20-22
2 x 0,5 mm
CEI EN
4 x 0,5 mm
50267-2-1
2 x 0,5 mm
2 x 0,5 mm
RG58
4
5
10
9
11
L. of cable 10 < 20 m
2
3G x 2,5 mm
2
2
2 x 1 mm
2
2
2 x 0.5 mm
2
2
4 x 0,5 mm
2
2
2 x 0,5 mm
2
2
2 x 0,5 mm
max. 10 m
1
3
2
1) Gearmotor unit
2) Incorporated control panel with radio transmitter
3) Transmission guide
4) Release device
5) Standard transmission arm
6) Key-switch selector
7) Flashing light movement indicator
8) Tuned antenna
9) Safety photocells
10) Indoor push button control
11) Safety sensitive profi le
* double-guide sectional door
SPRING BALANCED FULLY RETRACTABLE SWING OUT OVERHEAD DOOR
L. of cable 20 < 30 m
2
2
3G x 4 mm
2
2 x 1,5 mm
2
2 x 0,5 mm
2
4 x 0,5 mm
2
2 x 1 mm
2
2 x 0,5 mm
* single-guide sectional door