5.5 Preparing the transmission guide
The following applications are only examples, as the space required for unit installation and the accessories vary depending on
dimensions and therefore it is up to the installer to select the best solution.
1) Fasten the bracket to the tension device on the transmission guide using the supplied bolts and washers.
2) Position the transmission guide in the following manner:
- for sectional doors directly above spring-release coiling shaft (between 20 and 30 mm of the shaft's axis).
N.B.: if the distance between the coiling shaft and the top part of the door is between 300 and 600 mm, use the V122 arm (see
technical documentation attached);
- for overhead doors between 10 and 20 mm from the highest sliding point of the door.
N.B.: for pratially-retractable swing out counterweighted garage doors, use the V201 arm (see technical documentation attached).
M6
M6 x 20
V122
V201