7.2 Programming for partial opening
With the door is completely closed, set DIP switch 2 to ON (the signalling led fl ashes).
Press and keep the OPEN button pressed until the door reaches the desired point of opening...
...then press the ENC/RADIO button (if the signalling LED stays on the programming procedure is successfully complete).
Set DIP switch 2 back to OFF
7.3 Programming for decelerated opening when door is open (50% of the opening arc max.)
Note: before programming, deactivate the automatic closing by adjusting the A.C.T. Trimmer to its minimum setting.
With the gate completely open, press and keep pressed the ENC/RADIO button (the signalling programming led fl ashes quickly).
Set DIP switch 1 to ON (the signalling LED turns off).
Release the ENC/RADIO button (the signalling LED fl ashes slowly).
ON
+ E -
26V 17V 0V
M N
1
2
ACC. FUSE 3,15A-F
ZL56A
NE FUSE
MOTOR FUSE
1,6A-F
8A-F
OP.SENS.
OP / CL
OPEN
ENC/RADIO
SLOW.SENS
A.C.T.
CL.SENS.
AF