Ignition Detect; Ignition Control - Queclink GV200G User Manual

Gsm/gprs/gps tracker
Table of Contents

Advertisement

GV200G User Manual

3.3.5. Ignition Detect

The PIN 14 is DIN1 (Positive trigger). Its electrical conditions are:
Table 8: Electrical conditions of ignition detect
Logical State
Active
Inactive
It is strongly recommended to connect this pin to ignition key to support the power saving
function when the vehicle is off.
Another easy way is to connect PIN14 to a power output in the fuse box of the vehicle which
is only enabled after the vehicle is ignition on. For example: the power output for radio FM.

3.3.6. Ignition Control

DOUT1/2/3/4 can be used to control ignition key. They are Open-Drain type with no internal
pull-up resistor which also be used to control a relay. It means that the user has to connect a
pull-up resistor or a relay coil between the DOUT1/2/3/4 pin and any positive voltage (32V
max.) to generate a correct output. The DOUT1/2/3/4 pin can drive a continuous current of
0.2A.
TRACGV200GUM001
Electrical State
5.0V to 32V
0V to 3V or Open
Figure 8: Ignition detection