Electrical Conditions For Digital Inputs - Queclink GV200G User Manual

Gsm/gprs/gps tracker
Table of Contents

Advertisement

GV200G User Manual
The electrical conditions of it are:
Table 9: Electrical conditions of ignition control
Logical State
Enable
Disable
User can use this pin to control a relay output. An example to control the ignition key is
showed in following figure. Please refer to chapter 3.3.11 for the detail information on how to
drive a relay with digital output.
Figure 9: Example connection of ignition control

3.3.7. Electrical conditions for digital inputs

For negative trigger inputs the electrical conditions are:
Table 10: Electrical conditions of negative trigger digital inputs
Logical State
Active
Inactive
The example connection is showed as follow:
TRACGV200GUM001
Electrical State
<1.5V, drive current is 0.2A
Open or the pull-up voltage (max 32V)
Electrical State
0V to 0.8V
1.7V to 32V or Open
- 16 -