Ignition Detection; Digital Inputs - Queclink GV300 User Manual

Gsm/gprs/gps tracker
Hide thumbs Also See for GV300:
Table of Contents

Advertisement

GV300 User Manual

3.8. Ignition Detection

Table 7. Electrical Characteristics of Ignition Detection
Logical status
Active
Inactive
IGN (Pin3) is used for ignition detection. It is strongly recommended to connect this pin to
ignition key "RUN" position as shown above.
An alternative to connecting to the ignition switch is to find a non-permanent power source that
is only available when the vehicle is running, for example, the power source for the FM radio.
IGN signal can be configured to start transmitting information to the backend server when
ignition is on, and enter the power saving mode when ignition is off.

3.9. Digital Inputs

There are three general purpose digital inputs on GV300. They are all negative triggers.
Table 8. Electrical Characteristics of the Digital Inputs
Logical status
Active
Inactive
The following diagram shows the recommended connection of a digital input.
TRACGV300UM001
Electrical characteristics
5.0V to 32V
0V to 3V or open
Figure 10.
Typical Ignition Detection
Electrical characteristics
0V to 0.8V
Open
- 16 -