Carefully check the location where the range is to be
installed. For best performance, the range should be placed
away from drafts that may be caused by doors, windows, and
heating and air conditioning outlets.
To reduce the risk of personal injury and to reduce
accumulated smoke in the room, Dacor
recommends installing a range hood. A range hood should
project horizontally a minimum of 5 inches beyond the face of
the cabinets.
The range may be installed flush to the rear wall.
Dacor
®
recommends installing a non-combustible material on
the rear wall above the range and up to the vent hood. If a
non-combustible surface is not installed, a backguard must
be installed. It is not necessary to install non-combustible
materials behind the range below the countertop height.
Any openings in the wall behind the appliance or in the floor
underneath it must be sealed.
The minimum distance from the sides of the range above
the countertop to combustible side walls must be at least 10
inches.
p
lannIng The
®
strongly
cut-out Dimensions
I
nsTallaTIon
All dimensions shown are based on standard American
cabinets, 36 inches (914mm) high at the finished countertop
by 24 inches (610mm) deep, with a 25 inch (635mm) overall
countertop depth. When installing the range into nonstandard
cabinets, minimum clearances shown in the diagrams must
be maintained.
Gas and electrical Service
The shaded area shown denotes the location of the gas
inlet and the electrical junction box/receptacle. This is the
recommended location. For replacement purposes, the
location of the existing utilities may be utilized provided they
do not interfere with the sides or rear of the range. Check
local building codes for permissible gas valve locations.
An external manual shut-off valve must be installed between
the gas inlet and the range, for the purpose of turning on or
shutting off gas to the appliance.
The installation must allow for the following:
Access to the gas shut-off valve when the unit is installed.
Access to the remote circuit breaker panel/fuse box, when the
range is in place.
The gas supply piping and shut-off valve, and the electrical
junction box/receptacle must be located so they do not
interfere with the range when it is installed.
The junction box and gas shut off valve must be located
so that the range can be pulled out for service while the
appliance remains connected.
cuT-ouT DIMenSIonS
range Model
ER36D
ER48D
48" (1219mm)**
* Recommended
"e"
"F"
42" (1067mm)*
1
36
/
" (916mm)*
16
36" (914mm)**
54" (1372mm)*
48 ⅛" (1222mm)*
**Minimum