IMPorTanT: Observe all governing codes and ordinances during
planning and installation. Contact your local building department
for further information.
e
r
leCTrICal
equIremenTs
It is the owner's responsibility to ensure that the electrical
connection of this appliance is performed by a qualified
electrician. The electrical installation, including minimum supply
wire size and grounding, must be in accordance with the National
Electric code ANSI/NFPA 70-1993* (or latest revision) and local
codes and ordinances. A copy of this standard may be obtained
from:
National Fire Protection Association
1 Batterymarch Park
Quincy, Massachusetts 02269-9101
The correct voltage, frequency, and amperage must be
supplied to the appliance from a separate, grounded, circuit
that is protected by a properly sized circuit breaker or time
delay fuse. Refer to the chart below for requirements.
A 4-wire connection (not provided) is required to connect
the range to the junction box. The minimum wire gauge
suggested by Dacor
®
is 10 AWG. Consult local building codes
for the type and minimum wire gauge to use.
Suggested wiring color code: Black, white, red, and green.
The wiring needs to be long enough to allow the range
to be pulled out from the wall for service, while remaining
connected. See page 9 for further details.
eLecTrIc cIrcuIT reQuIreMenTS
range Model
circuit required
120/240VAC,
ER36D
120/240VAC,
ER48D
g
s
r
as
upply
equIremenTs
Check your local building codes for the proper method of
installation. In the absence of local codes, this appliance
should be installed in accordance with the National Fuel Gas
Code ANSI Z223.1.
Be certain that the appliance being installed is correct for
the gas service being provided (natural gas or LP gas). Also,
if operating the range at an altitude above 2000 ft. (600 m)
make sure it is equipped for high altitude operation. Refer to
the range data plate and the table on page 3 to determine the
correct model.
See the table below for gas supply pressure requirements.
The regulator inlet accommodates a 3/4" gas line. The range
ships with a 1/2" to 3/4" adapter connected to the regulator.
GaS SuPPLY PreSSure reQuIreMenTS
Gas Type
Manifold Pressure
Natural Gas
5" Water Column
Liquid Propane(LP)
10" Water Column

p
lannIng The
Total connected
Load
6.5kW (28A)
60Hz, 30A
10.0kW (42A)
60Hz, 50A
Minimum Gas
Supply Pressure
6" Water Column
11" Water Column
I
nsTallaTIon
p
d
roduCT
ImensIons
Finished Side
Panel
noTeS:
If you are installing the (optional) backguard, always install it
before sliding the range into place. See page 7.
Gas regulator access,
cover removed
Inlet
B
A
C
GaS - eLecTrIcaL acceSS DIMenSIonS
Model
"a"
ER36D
6 3/16"
ER48D
3 7/8"
range electrical access,
cover removed
conduit connection
hole in Bottom
D
Back of range
"B"
"c"
"D"
20"
12 1/4"
14 7/8"
19 3/8""
9 1/8""
17 5/8"