Electrical Connection - Dacor Epicure ER36D Installation Instructions Manual

Hide thumbs Also See for Epicure ER36D:
Table of Contents

Advertisement

e
C
leCTrICal
onneCTIon
WarnInG:
Wire the range only in compliance with local ordinances
The installer must connect the ground terminal (or lead)
on the appliance to a grounded, metallic, permanent wiring
system or grounding conductor.
Do not use an extension cord with this appliance. Such use
may result in fire, electric shock, or other personal injury.
Do not install a fuse in the neutral or ground circuit. A fuse
in the neutral or ground circuit may result in an electric
shock hazard.
connecting the range Wiring
1.
Make sure that the conduit and wire are long enough to allow
the range to be pulled out for service without disconnecting it.
I
nsTallaTIon
WarnInG
Put slack in electrical
wiring and gas line
I
nsTruCTIons
2.
Remove the electrical access cover to expose the opening in
the range electrical panel.
3.
Feed the wires through the hole underneath the range
electrical panel and secure the conduit or appliance wire.
4.
Connect the wires from the conduit or appliance wires to the
wires in the range electrical panel. Match the wire colors.
5.
Replace the electrical access cover.
electrical access cover
Gas regulator
access cover
Gas and electrical access covers
Junction Box Wiring Instructions
noTeS:
The power supply must be properly polarized. Reverse
polarity will result in continuous sparking of the electrodes,
even after flame ignition.
If there is any doubt as to whether the power supply is
properly polarized or grounded, have it checked by a qualified
electrician.
With the range positioned directly in front of the cabinet cutout,
feed the appliance wires into the electrical junction box. Then,
depending upon local codes, utilize one of the three methods on
pages 10 and 11 to connect the appliance to the junction box.
Back of range


Advertisement

Table of Contents
loading

This manual is also suitable for:

Epicure er48d

Table of Contents