Checking The Brake - GGP WBE 0701 Workshop Manual

Table of Contents

Advertisement

> 2 mm
9

Service manual

11.. Checking the brake

1 - Remove the starter assembly
10
2 - Check that the thickness of the friction pad (9)
is not less than 2 mm at its thinnest point.
3 - Make sure that the control lever (10) moves freely
and remove any remains of grass and mud.
4 - Refit the starter assembly
5 - Start the engine, release the lawnmower lever
and check that the engine stops within 3 secon-
ds.
6 - If it stops after 3 seconds, replace the entire as-
sembly
tion pad are not capable of ensuring compliance
2
with braking times.
pag. 2
Engine WBE 0701-WBE 0704
[
[
11.4], because the spring or the fric-
WARNING! Never return the lawnmower to
your client without checking brake efficien-
cy.
Release 00 - 02/2008
<< BACK >>
back to the index
[
6.1].
6.1].

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wbe 0704