SECTION 10G. SWITCHES
Contacts Open
No Continuity
Position
Continuity
OFF
None
STEP 4A
Contacts Closed
Continuity 0–0.5 Ohms
Position
Continuity
RUN
B+I+A
X+Y
STEP 4C
Contacts Closed
Continuity 0–0.5 Ohms
Position
Continuity
START
B+I+S
STEP 4E
Figure 10G-3. Ignition Switch Test Step 4
10G-3
ELECTRICAL SYSTEM
Contacts Closed
Continuity 0–0.5 Ohms
Position
Continuity
RUN
B+I+A
X+Y
STEP 4B
Contacts Closed
Continuity 0–0.5 Ohms
Position
Continuity
RUN
B+I+A
X+Y
STEP 4D
Contacts Closed
Continuity 0–0.5 Ohms
Position
Continuity
START
B+I+S
STEP 4F