Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
DOOR SWITCH
Door Switch
Door Lock/
Unlock
PTC
Refer to page 4-14 for the procedure for ac-
cessing the door switch.
To check the door switch at the CCU, perform
the following steps.
1.
Unplug washer or disconnect power.
2.
Disconnect the door lock/unlock sole-
noids connector DLS3 (see page 4-5)
from the CCU.
3.
Set the ohmmeter to the R X 1 scale.
4.
To test the door lock/unlock solenoids,
touch the ohmmeter test leads to the
indicated pins on connector DLS3. The
meter should indicate as follows:
Door Unlock Solenoid - Pins 1 & 2 =
infinite
Door Lock Solenoid - Pins 2 & 3 =
infinite
Pins 1 & 3 = 1-5 Ω
WARNING
Electrical Shock Hazard
5.
SET2
6.
DU3
7.
PR2
5.
Disconnect the door switch connector
DU3 (see page 4-5) from the CCU.
6.
To test the door switch, touch the ohm-
meter test leads to pins 1 and 2 at DU3.
The meter should indicate as follows:
Door Closed = 0 Ω
Door Open = infinite
5.
SET2
6.
DU3
7.
PR2
5-5
5
6
1 2 1 2
1 2
Temperature Sensor
Door Switch
Pressure switch Input low voltage
5
6
1 2 1 2
1 2
Temperature Sensor
Door Switch
Pressure switch Input low voltage
7