QUICK DIAGNOSTICS TEST
NOTES:
To cancel out of this mode rotate the selector knob. (This exits you out of the program.)
Press "CANCEL/DRAIN" button 2 times can advance to the next step of the procedure.
If the starting procedure fails, switch the knob and back to the CLEAN WASH cycle, the
repeat the starting procedure.
Indication
Factory Test Display
(7-SEGMENT LED)
OFF
1
(Phase LED rolling)
1
2
3
4
WARNING
Electrical Shock Hazard
Control Action
Door locks
Checks the EEPROM data's validity
Pump turns ON if the water level is detected to be
above the wash level
Turns hot valve inlet on (About 15s)
Turns bleach valve inlet on (About 15s)
Turns cold valve inlet on (About 15s)
Fill by cold water inlet valve to Level_wash
Motor reverse. Runs at normal washing speed.
(About 15s)
Pump turns ON to drain the washer
Drive motor to max speed
6-11
Actuators to be
Failure code
Checked
for failure mode
Door lock system
F13
Drain system
F03, F05, F14,
EEPROM test
F21, F23, F24,
F26, F30
Hot Water inlet valve
F01, F21, F23,
Cold Water inlet valve
F24
Bleach inlet valve
Reversing relay
F06, F07, F21,
Safety relay
F27
Motor thermistor
Tachometer signal
Drain system
F03, F21
Motor speed
F06, F07, F21,
Tap field relay
F27, F28