18. Remove the drive motor from the tub (see
page 4-20 for the procedure).
19. Remove the temperature sensor and
heater from the tub (see page 4-19 for
the procedure).
20. Release the two motor control unit wiring
standoffs from the tub. Squeeze in on the
standoff tabs to release the standoffs.
Motor Control Unit Wiring Standoffs
21. Remove the two shock absorbers from
the tub. To remove a shock absorber:
a) Remove the locking clips by squeez-
ing the tabs on the locking clips from
the base.
b) Using a pair of pliers, turn the top of
the shock absorber 90° so that the
locking tabs align with the slots in the
tub, and remove the shock absorber
(see the top right photo).
Shock Absorber
Locking Clip
Tabs
Turn Shock
Absorber Here
22. Remove the end of the vent tube from
the tub.
WARNING
Excessive Weight Hazard
Use two or more people to move and
install washer.
Failure to do so can result in back or
other injury.
23. To remove the tub and basket:
a) Lift the tub and basket assembly and
unhook the two suspension springs,
then remove the assembly from the
washer, and place it front-side down
on a padded surface.
Unhook Tub Springs
Continued on the next page.
4-25
Remove Vent Tube