NETGEAR GS700TP Software Administration Manual page 45

Smart switch
Hide thumbs Also See for NETGEAR GS700TP:
Table of Contents

Advertisement

GS700TP Smart Switch Software Administration Manual
The Basic PoE Configuration screen contains the following fields:
Power Status – Displays the online power source status. The possible field values are:
On – Indicates the power supply unit is functioning.
Off – Indicates the power supply unit is not functioning.
Faulty – Indicates the power supply unit is functioning, but an error has occurred. For
example, a power overload or a short circuit.
Nominal Power – Displays the actual amount of power the device can supply. The field
value is displayed in Watts.
Consumed Power – Displays the amount of the power used by the device. The field value
is displayed in Watts.
System Usage Threshold – Enter the percentage of power consumed before an alarm is
generated. The field value is 1-99 percent. The default is 95 percent.
Traps – Select the PoE device trap state. The possible field values are:
Enable – Enables PoE traps on the device.
Disable – Disables PoE traps on the device. This is the default value.
2. Enter the System Usage Threshold in the provided field.
3. Select either Enable or Disable in the Traps field.
4. Click APPLY to update the device.
Advanced
The PoE Advanced menu contains the following options:
"PoE Configuration"
"PoE Port Configuration"
PoE Configuration
The Advanced PoE Configuration screen contains system PoE information for enabling PoE on
the device, monitoring the current power usage, and enabling PoE traps.
To configure PoE on the device:
1.
Click System > PoE > Advanced > PoE Configuration. The Advanced PoE Configuration
screen displays:
3-11
v1.0, November 2009
Managing System Settings

Advertisement

Table of Contents
loading