Zone Options - Zones 1 To 16 - NAPCO GEM-P1664EX Programming Instructions Manual

Hide thumbs Also See for GEM-P1664EX:
Table of Contents

Advertisement

WI1387 7/05
ZONE OPTI ON S - ZONE S 1 T O 16 (ADDRESS 0900-1016)
ZONE OPTIONS
ZN16 ZN15 ZN14 ZN13
50ms Loop Response
(A)
Priority
Priority with Bypass
Auto-Bypass
Selective Bypass
Keyswitch Arming
Auto-Bypass Re-entry
Pre-Alarm Warning
Never Arm
24-Hour Zone
Alarm Output
Pulsed Alarm Output
PGM1 Output
PGM2 Output
Entry/Exit 1
Entry/Exit 2
Exit/Entry Follower
Auto Reset
Swinger Shutdown
Chime
Abort Delay
Power-up Delay
Day Zone Open
Day Zone Short
Alarm on Day Zone
Alarm Telco 1
Alarm Restore 1
Trouble Telco 1
Trouble Restore 1
Alarm Telco 3
Alarm Restore 3
Trouble Telco 3
Trouble Restore 3
No EOL Resistor
Trouble on Open
Trouble on Short
Zone Area 1
Zone Area 2
Zone Area 3
Zone Area 4
Interior (Stay) Bypass
Keypad Sounder on Alarm
2-Wire Smoke Detectors
(B)
Fire (C)
Fire Alarm Verification
(C)
RESERVED
Zone ANDing Group 1
Zone ANDing Group 2
Zone ANDing Group 3
Zone ANDing Group 4
Sensor Watch
RESERVED
Chime 2
See steps listed at
bottom of page
Step 1
When the Easy Program Menu is used, these features are enabled by default.
Enabled when "Enable SIA CP-01 Features?" is activated (Answer "Yes" in the EZ Programming Menu).
Disabled when "Enable SIA CP-01 Features?" is activated (Answer "Yes" in the EZ Programming Menu). Disable Auto-Reset on non-fire zones for SIA CP-01 installations.
NOTE: (Address Location 0942 can only be programmed as "blank (•) blank (•)", "4 blank (•)", "8 blank (•)" or "C blank (•)".
1. Select the desired zone option.
2. Enable desired options for each zone
by drawing a circle
ZONE OPTIONS
corresponding binary data value. NOTE:
s
50ms Loop Response
No circle = feature disabled.
Priority
Priority with Bypass
Auto-Bypass
Selective Bypass
L
NAPCO Security Systems
ZONES 13-16
LEFT DATA VALUES
ADDRESS
)
(CIRCLE
L
ADDR R
8
4
2
1
0964
8
4
2
1
0965
8
4
2
1
0966
8
4
2
1
0967
8
4
2
1
0968
8
4
2
1
0969
8
4
2
1
0970
8
4
2
1
0971
8
4
2
1
0972
8
4
2
1
0973
8
4
2
1
0974
8
4
2
1
0975
8
4
2
1
0976
8
4
2
1
0977
8
4
2
1
0978
8
4
2
1
0979
8
4
2
1
0980
8
4
2
1
0981
8
4
2
1
0982
8
4
2
1
0983
8
4
2
1
0984
8
4
2
1
0985
8
4
2
1
0986
8
4
2
1
0987
8
4
2
1
0988
8
4
2
1
0989
8
4
2
1
0990
8
4
2
1
0991
8
4
2
1
0992
8
4
2
1
0993
8
4
2
1
0994
8
4
2
1
0995
8
4
2
1
0996
8
4
2
1
0997
8
4
2
1
0998
8
4
2
1
0999
8
4
2
1
1000
8
4
2
1
1001
8
4
2
1
1002
8
4
2
1
1003
8
4
2
1
1004
8
4
2
1
1005
8
4
2
1
(•)
1006
8
4
2
1
1007
8
4
2
1
1008
8
4
2
1
(•)
1009
8
4
2
1
1010
8
4
2
1
1011
8
4
2
1
1012
8
4
2
1
1013
8
4
2
1
1014
8
4
2
1
1015
8
4
2
1
1016
Step 2
Step 4
Step 4
around its
ZONES 9-12
ZONES 5-8
RIGHT DATA VALUES
LEFT DATA VALUES
)
(CIRCLE
(CIRCLE
ZN12 ZN11 ZN10 ZN9 ZN8 ZN7 ZN6 ZN5
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
(•)
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
(•)
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
Step 2
Step 2
3. Search table below for data entry.
DIGIT VALUE DATA ENTRY
DIGIT VALUE DATA ENTRY
.
8
8
4
2 1
Blank (
)
4 2 1
8
4
2 1
1
8
4 2 1
8
4
2 1
2
8
4 2 1
3
8
8
4
2
1
4
2
1
8
4
2 1
4
8
4 2 1
8
4
2 1
5
8
4 2 1
6
8
4
2 1
8
4 2 1
7
8
8
4
2 1
4 2 1
X
GEM-P1664EX Programming Instructions
ADDRESS
RIGHT DATA VALUES
)
L
ADDR R
ZN4 ZN3 ZN2 ZN1
4
2
1
0900
8
4
2
1
0901
8
4
2
1
0902
8
4
2
1
0903
8
4
2
1
0904
8
4
2
1
0905
8
4
2
1
0906
8
4
2
1
0907
8
4
2
1
0908
8
4
2
1
0909
8
4
2
1
0910
8
4
2
1
0911
8
4
2
1
0912
8
4
2
1
0913
8
4
2
1
0914
8
4
2
1
0915
8
4
2
1
0916
8
4
2
1
0917
8
4
2
1
0918
8
4
2
1
0919
8
4
2
1
0920
8
4
2
1
0921
8
4
2
1
0922
8
4
2
1
0923
8
4
2
1
0924
8
4
2
1
0925
8
4
2
1
0926
8
4
2
1
0927
8
4
2
1
0928
8
4
2
1
0929
8
4
2
1
0930
8
4
2
1
0931
8
4
2
1
0932
8
4
2
1
0933
8
4
2
1
0934
8
4
2
1
0935
8
4
2
1
0936
8
4
2
1
0937
8
4
2
1
0938
8
4
2
1
0939
8
4
2
1
0940
8
4
2
1
0941
8
4
2
1
0942
(•)
8
4
2
1
0943
8
4
2
1
0944
8
4
2
1
(•)
0945
(•)
8
4
2
1
0946
8
4
2
1
0947
8
4
2
1
0948
8
4
2
1
0949
8
4
2
1
0950
8
4
2
1
0951
8
4
2
1
0952
8
Step 4
Step 4
For notes (A), (B) and (C), see next page.
4. Enter data in address locations (left and right
digits). Press [Enter] or [ON/OFF] to save.
8
ADDRESS LOCATION
9
0
L
ADDR
B
blank (•)
0490
C
D
NOTE: Dark shaded boxes = option not available.
E
See Direct Address Programming Example page 22.
F
Page 45
ZONES 1-4
)
(CIRCLE
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
Step 2
R
1

Advertisement

Table of Contents
loading

Table of Contents