ZONE OPTI ON S - ZONE S 1 T O 16 (ADDRESS 0490-0595)
ZONE OPTIONS
ZN16 ZN15 ZN14 ZN13
50ms Loop Response
(A)
%
$
Priority
Priority with Bypass
Auto-Bypass
%
Selective Bypass
$
Keyswitch Arming
Auto-Bypass Re-entry
Pre-Alarm Warning
Never Arm
24-Hour Zone
%
$
Alarm Output
$ Pulsed Alarm Output
PGM1 Output
PGM2 Output
$ Entry/Exit 1
Entry/Exit 2
$ Exit/Entry Follower
&
$
Auto Reset
&
Swinger Shutdown
$
$ Chime
Abort Delay
Power-up Delay
Day Zone Open
Day Zone Short
Alarm on Day Zone
$ Alarm Telco 1
Alarm Restore 1
Trouble Telco 1
Trouble Restore 1
Alarm Telco 3
Alarm Restore 3
Trouble Telco 3
Trouble Restore 3
No EOL Resistor
Trouble on Open
Trouble on Short
$ Zone Area 1
Zone Area 2
Interior (Stay) Bypass
Keypad Sounder on Alarm
$ 2-Wire Smoke Detectors
(B)
$ Fire (C)
Fire Alarm Verification
(C)
RESERVED
Zone ANDing Group 1
Zone ANDing Group 2
Zone ANDing Group 3
Zone ANDing Group 4
Sensor Watch
RESERVED
Chime 2
$
When the Easy Program Menu is used, these features are enabled by default.
%
Enabled when "Enable SIA CP-01 Features?" is activated (Answer "Yes" in the EZ Programming Menu).
&
Disabled when "Enable SIA CP-01 Features?" is activated (Answer "Yes" in the EZ Programming Menu). Disable Auto-Reset on non-fire zones for SIA CP-01 installations.
!
1
!
!
1. Select the desired
zone option.
ZONE OPTIONS
s
50ms Loop Response
Priority
Priority with Bypass
Auto-Bypass
Selective Bypass
X
GEM-P1632 Programming Instructions
ZONES 13-16
LEFT DATA VALUES
ADDRESS
"
)
(CIRCLE
L
ADDR R
8
4
2
1
8
4
2
1
0546
8
4
2
1
0547
8
4
2
1
0548
8
4
2
1
0549
8
4
2
1
0550
8
4
2
1
0551
8
4
2
1
0552
8
4
2
1
0553
8
4
2
1
0554
8
4
2
1
0555
8
4
2
1
0556
8
4
2
1
0557
8
4
2
1
0558
8
4
2
1
0559
8
4
2
1
0560
8
4
2
1
0561
8
4
2
1
0562
8
4
2
1
0563
8
4
2
1
0564
8
4
2
1
0565
8
4
2
1
0566
8
4
2
1
0567
8
4
2
1
0568
8
4
2
1
0569
8
4
2
1
0570
8
4
2
1
0571
8
4
2
1
0572
8
4
2
1
0573
8
4
2
1
0574
8
4
2
1
0575
8
4
2
1
0576
8
4
2
1
0577
8
4
2
1
0578
8
4
2
1
0579
8
4
2
1
0580
8
4
2
1
0581
8
4
2
1
0582
8
4
2
1
0583
8
4
2
1
0584
8
4
2
1
(•)
0585
8
4
2
1
0586
8
4
2
1
0587
8
4
2
1
(•)
0588
8
4
2
1
0589
8
4
2
1
0590
8
4
2
1
0591
8
4
2
1
0592
8
4
2
1
0593
8
4
2
1
0594
8
4
2
1
0595
!
!
!
2
4
2. Enable desired options for
each zone by drawing a circle
" around its corresponding
binary data value. NOTE: No
circle = feature disabled.
ZN04 ZN03 ZN02 ZN01
8
4
2
1
Draw Circle
ZONES 9-12
ZONES 5-8
RIGHT DATA VALUES
LEFT DATA VALUES
"
)
(CIRCLE
(CIRCLE
ZN12 ZN11 ZN10 ZN9 ZN8 ZN7 ZN6 ZN5
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
(•)
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
(•)
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
!
4
2
!
3. Search table below
for data entry.
DIGIT VALUE DATA ENTRY
DIGIT VALUE DATA ENTRY
.
8
4
2 1
Blank (
)
8
4 2 1
8
4
2 1
1
8
4 2 1
8
4
2 1
2
8
4 2 1
8
4
2
1
3
8
4
2
1
8
4
2 1
4
8
4 2 1
8
4
2 1
5
8
4 2 1
8
4
2 1
6
8
4 2 1
8
4
2 1
7
8
4 2 1
ADDRESS
RIGHT DATA VALUES
"
)
L
ADDR R
ZN4 ZN3 ZN2 ZN1
4
2
1
0490
8
4
2
1
0491
8
4
2
1
0492
8
4
2
1
0493
8
4
2
1
0494
8
4
2
1
0495
8
4
2
1
0496
8
4
2
1
0497
8
4
2
1
0498
8
4
2
1
0499
8
4
2
1
0500
8
4
2
1
0501
8
4
2
1
0502
8
4
2
1
0503
8
4
2
1
0504
8
4
2
1
0505
8
4
2
1
0506
8
4
2
1
0507
8
4
2
1
0508
8
4
2
1
0509
8
4
2
1
0510
8
4
2
1
0511
8
4
2
1
0512
8
4
2
1
0513
8
4
2
1
0514
8
4
2
1
0515
8
4
2
1
0516
8
4
2
1
0517
8
4
2
1
0518
8
4
2
1
0519
8
4
2
1
0520
8
4
2
1
0521
8
4
2
1
0522
8
4
2
1
0523
8
4
2
1
0524
8
4
2
1
0525
8
4
2
1
0526
8
4
2
1
0527
8
4
2
1
0528
8
4
2
1
0529
8
4
2
1
0530
(•)
8
4
2
1
0531
8
4
2
1
0532
8
4
2
1
(•)
0533
(•)
8
4
2
1
0534
8
4
2
1
0535
8
4
2
1
0536
8
4
2
1
0537
8
4
2
1
0538
8
4
2
1
0539
8
4
2
1
0540
8
!
!
!
2
4
4
!
4. Enter data in address locations
(left and right digits). Press [Enter]
or [ON/OFF] to save.
8
ADDRESS LOCATION
9
L
ADDR
0
blank (•)
0490
B
C
NOTE: Dark shaded data value box
shows option not available.
D
E
N O T E :
S e e
F
Programming Example on page 22.
L
NAPCO Security Systems
ZONES 1-4
"
)
(CIRCLE
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
!
2
R
1
D i r e c t
A d d r e s s

Advertisement

Table of Contents
loading

Table of Contents