Prerequisites For Setting Up The Crash Capture; Setting Up Nodes For Crash Capture - HP IBRIX X9720 Administrator's Manual

Hide thumbs Also See for IBRIX X9720:
Table of Contents

Advertisement

4.
After the core dump is created, the failed node reboots and its state changes to Up,
FailedOver.

Prerequisites for setting up the crash capture

The following parameters must be configured in the ROM-based setup utility (RBSU) before a crash
can be captured automatically on a file server node in failed condition.
1.
Start RBSU. Reboot the server, and then Press F9 Key.
2.
Highlight the System Options option in main menu, and then press the Enter key. Highlight
the Virtual Serial Port option (below figure), and then press the Enter key. Select the COM1
port, and then press the Enter key.
3.
Highlight the BIOS Serial Console & EMS option in main menu, and then press the Enter key.
Highlight the BIOS Serial Console Port option and then press the Enter key. Select the COM1
port, and then press the Enter key.
4.
Highlight the BIOS Serial Console Baud Rate option, and then press the Enter key. Select the
1 15200 Serial Baud Rate.
5.
Highlight the Server Availability option in main menu, and then press the Enter key. Highlight
the ASR Timeout option and then press the Enter key. Select the 30 Minutes, and then press
the Enter key.
6.
To exit RBSU, press Esc until the main menu is displayed. Then, at the main menu, press F10.
The server automatically restarts.

Setting up nodes for crash capture

IMPORTANT:
before starting the steps in this section.
To set up nodes for crash capture, complete the following steps:
1.
Enable crash capture. Run the following command:
ibrix_host_tune -S { -h HOSTLIST | -g GROUPLIST } -o
trigger_crash_on_failover=1
Complete the steps in
"Prerequisites for setting up the crash capture" (page 55)
Capturing a core dump from a failed node
55