Fs Unit (Flow Selector Unit) - Toshiba MMU-AP0072H2UL Engineering Data Book

208/230 v, 60 hz; 460 v, 60 hz
Hide thumbs Also See for MMU-AP0072H2UL:
Table of Contents

Advertisement

5
Outdoor unit

5-11. FS unit (Flow Selector unit)

Specifications
Model Name
Power supply
Connectable indoor unit capacity (kBtu/h)
Connectable indoor units
Dimension
Total Weight (lbs)
Connecting port dia.
(Indoor unit side)
Connecting port dia.
(Outdoor unit side)
Connection
External view
RBM-Y0383FUL, RBM-Y0613FUL
Refrigerant pipe connecting port (Discharge gas)
Refrigerant pipe connecting port (Liquid)
Refrigerant pipe connecting port (Suction gas)
■ Wiring Diagram
RBM-Y0963FUL
Refrigerant pipe connecting port (Discharge gas)
Refrigerant pipe connecting port (Liquid)
Refrigerant pipe connecting port (Suction gas)
1.10"(28)
2.20"(56)
■ Wiring Diagram
Height (in)
Width (in)
Depth (in)
Liquid side (in)
Gas side (in)
Liquid side (in)
Discharge gas side (in)
Suction gas side (in)
Outdoor unit side
(4.73"(120))
6.30"(160)
(4.73"(120))
0.83"(21)
1.73"(44)
3.43"(87)
RBM-Y0613FUL Only
Ground Screw
CN01
CN10(WHI)
(RED)
Control P.C Board
MCC-1431
CN02(GRN)
BRW
BLU YEL
WHI ORN
Attached wire (Control wiring)
Outdoor unit side
(4.73"(120))
7.88"(200)
3.7"(94)
Ground Screw
CN01
CN10(WHI)
(RED)
Control P.C Board
MCC-1431
CN02(GRN)
BRW
BLU YEL
WHI ORN
RBM-Y0383FUL
230 V (208/230 V) 3phase 60 Hz
Below 38
5
7.49
9.77
6.3
11
3/8"
5/8"
3/8"
1/2"
5/8"
12.6"(320)(Hanging bolt pitch)
9.77"(248)
Refrigerant pipe connecting port (Liquid)
Refrigerant pipe connecting port (Gas)
(4.73"(120))
Indoor unit
Attached wire (Power supply)
Control P.C Board
for indoor unit
CN67
(BLK)
CN81
(BLK)
Power supply
single phase
208/230 V, 60 Hz
18.5"(470) (Hanging bolt pitch)
15.8"(400)
(4.73"(120))
Indoor unit
Attached wire (Power supply)
Control P.C Board
for indoor unit
CN67
(BLK)
CN81
(BLK)
Power supply
single phase
208/230 V, 60 Hz
Attached wire (Control wiring)
99
RBM-Y0613FUL
38 to below 61
8
7.49
9.77
6.3
13
3/8"
5/8"
3/8"
1/2"
5/8"
Blaze connection
Indoor unit side
Ø0.87"(22.2)
Knockout hole for power wiring
Ø0.79"(20)
Hole for control wiring
5.39" (137)
2.13"(54)
2.95"(75)
Indoor unit
ground screw
Indoor unit side
Refrigerant pipe connecting port (Gas)
Refrigerant pipe connecting port (Liquid)
Ø0.87"(22.2)
Knockout hole for power wiring
Ø0.79"(20)
Hole for control wiring
2.64"(67)
3.70"(94)
6.93"(176)
Indoor unit
ground screw
RBM-Y0963FUL
61 to 96 or less
8
7.88
15.8
7.88
20
1/2"
7/8"
1/2"
3/4"
7/8"
(Unit: in (mm))

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents