5
Outdoor unit
Single unit (System with ducted indoor units)
Outdoor unit model name
Nominal voltage
Power Supply
Voltage range
Nominal capacity
Rated capacity
Cooling
Rated power consumption
Rated EER
Nominal capacity
Rated capacity
Heating
Rated power consumption
Rated COP
Starting Current
Height
Packing
Width
Depth
Dimension
Height
Unit
Width
Depth
Packed
Total Weight
Unit
Color
Type
Compressor
Motor output
Fan
Fan unit
Motor output
Air volume
Maximum external static pressure
Heat exchanger
Name
Refrigerant
Charged refrigerant amount
High-pressure switch
Protective devices
MCA
Electrical
Unit
specifications
MOCP
Type
Liquid
Diameter
Type
Suction
gas
Diameter
Refrigerant
piping
Type
Discharge
gas
Diameter
Type
Balance
Diameter
Maximum capacity of combined indoor units
Indoor units
Maximum number of indoor units
Cooling
Operation temperature range
Heating
Cooling
Sound pressure level
Heating
(*1) Rated conditions
Cooling: Indoor air temperature 80 °F DryBulb/67 °F WetBulb, Outdoor air temperature 95 °F DryBulb
Heating: Indoor air temperature 70 °F DryBulb, Outdoor air temperature 47 °F DryBulb/43 °F WetBulb
Equivalent piping length: 25 ft, Height difference: 0 ft
(*2) Value for only outdoor unit
(*3) Setting is necessary
(*4) The amount does not consider extra piping length. Refrigerant must be added on site in accordance with the actual piping length.
(*5) High-pressure switch / High-pressure sensor / Low-pressure sensor / Fusible plug / PC board fuse / Inverter overload protector
(*6) Select wire size based on the larger value of MCA.
MCA: Minimum Circuit Amps (minimum circuit Amps required for power supply design.)
(*7) MOCP: Maximum Overcurrent Protection (Amps)
(*8) This specification is value as of June, 2013, please note that specification is subject to change without notice.
MMY-
MAP0724FT6UL
V/Ph/Hz
V
(*1)
72
kBtu/h
70
(*2)
kW
5.64
Btu/W
12.4
(*1)
81
kBtu/h
77
(*2)
kW
6.35
W/W
3.55
A
In
76.3
In
41.8
In
32.6
In
72.9
In
39.0
In
30.7
lbs
691
lbs
658
kW
2.3 × 2
kW
1.0
cfm
5,120
(*3)
In WG
0.20
(*4)
lbs
25.4
psi
(*6)
A
19
(*7)
A
25
In
1/2"
In
7/8"
In
3/4"
In
3/8"
11
FDB
FWB
dB(A)
56.0
dB(A)
58.0
44
MAP0964FT6UL
460 / 3 / 60
414 Minimum / 506 Maximum
96
92
7.79
11.8
108
103
8.52
3.54
Soft Start
76.3
50.5
32.6
72.9
47.6
30.7
863
826
Silky shade (Munsell 1Y8.5/0.5)
Hermetic twin rotary compressor
2.1 × 3
Propeller fan
1.0
7,060
0.16
Finned tube
R410A
25.4
OFF: 420
ON: 540
(*5)
28
35
Flare connection
1/2"
Brazing connection
7/8"
Brazing connection
3/4"
Flare connection
3/8"
80 to 120%
15
14 to 109
-4 to 60
62.0
63.0
MAP1204FT6UL
120
118
10.04
11.8
135
113
9.10
3.64
76.3
50.5
32.6
72.9
47.6
30.7
863
826
2.7 × 3
1.0
7,620
0.16
25.4
30
35
1/2"
1-1/8"
3/4"
3/8"
19
63.5
65.5