Glossary - GE CS5500 Programming Manual

Table of Contents

Advertisement

Term
st
1
Keypad Function
200Bd FSK Channel
24-hour
24-hour Clock
nd
2
Keypad Function
2-wire Smoke Detectors A menu option that enables the 2-wire smoke detector in the control panel. A
4/6 Digit Codes
4+2 Code
4+2 Restore Code
45 Minute Retry
5 sec silence
A
Abort
Accept beep
Access Code
Access reader
Account Code
Activate Relay
Active
Address Message
9 G
LOSSARY
Definition
A menu entry that groups keypad options that enable home automation
commands. The commands activate the primary function of a keypad. These
options are With PIN and Without PIN.
A menu option that sets the channel used by the selected zone, zone type or
event for 200Bd FSK protocol. The zones between 1 and 99 can be directed to
separate channels. The zones between 100 and 168 follow the 200Bd FSK
Channel as specified on the zone type.
A zone where reaction is not dependent on the arm/disarm state of the system. It
is permanently active 24 hours a day unless bypassed by forced arming. An
example of a 24-hour zone is a fire, panic or glassbreak zone.
A menu option that switches between 24-hour and 12-hour notation.
A menu option that enables the home automation command that activates the
secondary function of a keypad.
2-wire smoke detector is connected to the control panel with two wires instead of
four. A maximum number of three 2-wire smoke detectors can be connected.
A menu option that specifies whether a four or six digit code is used.
A menu option that specifies the event code sent to the central station indicating a
4+2 alarm. The code is six digits long – four digits for the account code and two
digits for the zone ID. The zone ID refers to the zone that is in alarm.
A menu option that specifies the event code sent to the central station indicating a
4+2 restore. The code is six digits long – four digits for the account code and two
digits for the zone ID. The zone ID refers to the zone that is in alarm.
A menu option that causes the panel to try to arm after every 45 minutes of
inactivity until the next Opening time, or until the system is armed. The 45-minute
timer is extended when there is activity in the building. This causes the Ready
LED to turn off and on. If closing reports are sent, the user code is 97.
See also Partitions Autoarming
A menu option that silences the pulsing keypad sounder for five seconds when a
key is pressed.
To cancel an action, for example, to cancel an alarm report.
A control panel sound confirming the acceptance of a code, command or value
update.
A menu option that specifies the eight-digit access code sent by the up/download
software to the control panel. The panel permits downloading to occur when it
receives this code.
See also User Code
See CS1700 Proximity Readers
A menu option that specifies the unique code sent from the modem in the control
panel to the central station. The central station uses this code to identify and
charge the user. Separate account codes can be set up for each phone number
and each partition. This is also known as the account number.
A menu option that activates the CS1700 proximity reader's built in relay driver
instead of an external relay driver.
A menu option that specifies the days of the week that a particular schedule is
active. If this option is set to Holidays, the schedule is active on the dates
specified in Date of holidays.
A menu command that records the address message. This message is sent by the
CS535 voice module and states where an event has occurred. (Recording)
A menu command that plays back the address message. (Playback)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents