Page 2
Document number/revision: 1036547E. Disclaimer The information in this document is subject to change without notice. GE, in keeping pace with technological advances, is a company of product innovation. Therefore, it is difficult to ensure that all information provided is entirely accurate and up-to-date. GE accepts no...
Preface This is the GE KTD-405/KTD-405A Controller Keypad User Manual. This document includes an overview of the product and detailed instructions explaining: • how to install a KTD 405/KTD-405A keypad; and • how to program and operate a KTD-405/KTD-405A keypad.
Page 6
KTD-405/KTD-405A Controller Keypad User Manual...
Chapter 1 KTD-405/KTD-405A overview This chapter provides an explanation of the conventions in this document and an overview of your keypad. In this chapter: Product overview ......... . . 4 Operating modes.
Product contents The KTD-405 (Figure 1) and KTD-405A (Figure 2) packages, in addition to the items shown, include this KTD-405/KTD-405A Controller Keypad User Manual (1036547) and a quick reference guide (1047307).
Chapter 1 KTD-405/KTD-405A overview Operating modes The KTD-405 can be programmed to operate in two modes: standard Digiplex or zone (DVMR/multiplexer/ ® PTZ control). (See Appendix A, Sample configurations and charts for layout samples of these modes.) Note: Be aware that the addressing between domes and multiplexers is offset. When setting up and controlling your cameras...
System controller mode is an extension of standard and hybrid Digiplex modes, a mode that allows use of the KTD-405 with the HDS (High Density Switch) system controller. In this type of system, each user is assigned a user number that determines the user’s access privileges for each of the system resources. Users must log on to the keypad using their assigned user number.
Chapter 2 Installation This chapter shows all the connections you’ll need to make to get your keypad and all the peripheral devices working within a diverse video surveillance network. In this chapter: Installation guidelines........8 Back panel connections .
• Your system should contain only one RS-422 chain of devices. Only one KTD-405 keypad should be in that chain, which can contain any number of other RS-422-only keypads such as KTD-404s.
KTD-405 connections Adhere to all installation guidelines while making connections, including your local codes and those provided Installation guidelines on page 8. Figure 5. KTD-405 back panel connections RS-232 programming port (future use) RJ45 control cable (GE equipment I/O box uses two different RJ45 cables.
Figure 6. KTD-405A back panel connections RS-232 programming port (future use) RJ11 audio cable I/O box Audio port RJ45 control cable (GE equipment Power supply uses two different RJ45 cables. You RS-485 and RS-422 in/out Power cord must use the RJ45 cable provided RS-485 termination switch with the unit.)
KTD-405/KTD-405A Controller Keypad User Manual Twisted-pair connections The twisted-pair connections are available to connect additional devices or for existing installations where individual wires were used to connect to the old phone-style I/O box. Easy-to-use RJ-cable connections are also available on the new I/O box. See RJ-cable connections on page 11.
Adhere to all installation guidelines while making connections, including your local codes and those provided Installation guidelines on page 8. Figure 9. Connecting a keypad (KTD-405 shown) to a multiplexer or DVMRe (shown) and domes 1 2 3 4 5 6 7 8 EARTH GROUND...
Connecting multiple keypads with RJ45 cables Adhere to all installation guidelines while making connections, including your local codes and those provided Installation guidelines on page 8. Figure 10. KTD-405 and KTD-405A connections via RJ45 cables Observe polarity for: • audio • RS-422 •...
Connecting multiple keypads with STP cable Adhere to all installation guidelines while making connections, including your local codes and those provided Installation guidelines on page 8 Figure 11. KTD-405 and KTD-405A connections via STP cables Observe polarity for: • audio • RS-422 •...
KTD-405/KTD-405A Controller Keypad User Manual Connecting new and old I/O boxes Adhere to all installation guidelines while making connections, including your local codes and those provided Installation guidelines on page 8. Note: For additional connection details about the old I/O boxes, see Appendix D. Old I/O Box Connections.
Chapter 2 Installation Setting audio attenuation When using a KTD-336 audio converter, set the attenuation jumpers to the ON position (Figure 13). The attenuation jumpers are located on the audio/IO card, which is attached to the keypad’s base plate. When not using an audio converter, leave the attenuation jumpers in their default OFF position.
Page 22
KTD-405/KTD-405A Controller Keypad User Manual...
Chapter 3 Programming This chapter explains the programming modes and goes through the various steps you’ll need to follow to program your keypad. In this chapter: Programming modes........20 Supervisor programming .
KTD-405/KTD-405A Controller Keypad User Manual Programming modes There are different programming modes for the keypad: • Supervisor programming mode: Establishes such essentials as the keypad’s nonvolatile memory, title and many fundamental operating parameters, and allows flexible system setup. • User programming mode: Establishes the keypad’s system architecture for operations.
Chapter 3 Programming Entering programming modes To enter programming mode, do the following: Figure 15. Normal operating display 1. When you provide power to the unit, the normal operating display appears CAMERA 0 (Figure 15). MONITOR 1 Figure 16. ENTER PROGRAMMING CODE menu 2.
Figure 27 on page 26 of this menu. This is a critical number since it is needed to change any of the access codes. Be sure to store the new number in a safe place. If the number is lost, GE Security technical support can help you reset the keypad to factory defaults.
Page 27
KB3 PTZ PROTOCOL? this menu setting will remain at the default (+)=YES (-)=NO NEXT value of NO. However, if the KTD-405 you are using in a system that needs to communicate PTZ commands to a Calibur CBR-KB3/J keypad or ProBridge, you may need to select YES so that the KTD-405 communicates properly with these devices.
Page 28
KTD-405/KTD-405A Controller Keypad User Manual Figure 21. KEYPAD LOCKOUT PRIORITY displays 6. The keypad lockout priority menu (Figure 21) allows the supervisor to set up a KEYPAD LOCKOUT PRIOITY hierarchical relationship amoung keypads in 0=OFF 9=LOW NEXT the system so that keypads with a higher...
Page 29
Chapter 3 Programming By changing the lowest user programmed preset from the deault 58 to a lower number, you can make more presets available to keypad users. Note: Pressing store then one of the four aux buttons prompts you to press store again, which sets the quick store position.
Page 30
KTD-405/KTD-405A Controller Keypad User Manual 14. At the PROGRAM SOFT KEYS display, press and hold the seq key to return to the normal operating display or press Figure 27. CHANGE ACCESS CODES displays 15. Pressing or the side of the zoom, focus,...
Page 31
Chapter 3 Programming Figure 28. BAUD RATE display 16. Pressing or the side of the zoom, focus, or iris key (in Figure 27) takes you to the BAUD RATE (KBOS) 0 BAUD RATE display (Figure 28). To change 0=DFLT, 9, 19, 38 NEXT the baud rate used for RS-485 communication, enter the value here.
KTD-405/KTD-405A Controller Keypad User Manual User programming As explained in Entering programming modes on page 21, to enter the user menus, from the ENTER PROGRAMMING CODE menu, press 5-7-9-seq. This brings up the OPERATING MODE menu (Figure 31). Figure 31. OPERATING MODE menu...
Page 33
Chapter 3 Programming Figure 33. Access menus 6. The following access menus (Figure 33) are used to restrict the keypad from addressing CAMERA 000 ACCESS? specified sites in the system. (+)=YES (-)=NO NEXT The access menus enable you to allow access for each camera, monitor, DSR/ MONITOR 01 ACCESS? VCR, and multiplexer.
Page 34
KTD-405/KTD-405A Controller Keypad User Manual Figure 36. MONITOR OFFSET display 12. By default, the selected monitor number corresponds to the number of the matrix MONITOR OFFSET switcher output to which it is connected. For NUMBER: 0 NEXT example, if monitor 12 appears in the keypad’s display window and a camera...
Chapter 3 Programming Zone menus Remember that the addressing between domes and multiplexers is offset. When setting up and controlling your cameras in zone mode, refer to Zone receiver site addressing on page 65). To program your keypad in zone mode, do the following: Figure 38.
Page 36
KTD-405/KTD-405A Controller Keypad User Manual Figure 43. Zone hub display 6. The next display mentions zone hubs (Figure 43). A hub is the main controlling ZONE 01 HUB: DVMRE DUP device in a zone. Hub choices are DVMRE ( , )=SELECT...
Page 37
Chapter 3 Programming Figure 48. Annunciation menu 11. The annunciation menu (Figure 48) is for future use. When annunciation is enabled, ANNUNCIATION? the keypad displays the first, second, and (+)=YES (-)=NO NEXT third call-in/alarm on thee LCD and stores up to 32 call-in requests.
KTD-405/KTD-405A Controller Keypad User Manual Remote programming At the ENTER PROGRAMMING CODE menu, press 9-5-1-seq to display the REMOTE PROGRAMMING menu, which allows you to program devices such as cameras and VCRs, as shown in the tree in Figure 51.
Chapter 3 Programming CyberScout shadow tours This section explains how to program CyberScout shadow tours. Note: Refer to the CyberDome Programming Manual for the programming of CyberDome tours. To program a CyberScout ShadowTour™, do the following: Figure 52. Normal operating display 1.
Page 40
KTD-405/KTD-405A Controller Keypad User Manual...
Chapter 4 Operation This chapter explains how to operate your keypad. It also describes the different operating modes, standard Digiplex mode and zone mode. In this chapter: Operating your keypad ........38 Standard Digiplex mode .
KTD-405/KTD-405A Controller Keypad User Manual Operating your keypad Table 3 shows the default functions for the keypad’s keys in normal and shifted mode (shaded cells). To select the shifted mode, press and hold esc and then press the key. Some keys can be changed to other functions.
Page 43
Chapter 4 Operation Table 3. Normal and shifted key functions (continued) Function find With number keys, selects PTZ position saved by the previous store command for selected camera site. Step +zoom - Controls the zoom function on selected receiver site’s motorized zoom lens. PTZ lockout on/off.
Page 44
KTD-405/KTD-405A Controller Keypad User Manual Table 3. Normal and shifted key functions (continued) Function Places selected DSR, VCR, or DVMRe in record mode. Home. Sends current camera to preset 0. Toggles selected multiplexer’s full-screen picture between normal and 2X magnification.
Chapter 4 Operation Standard Digiplex mode When you provide power to the unit, the normal operating display appears (Figure 55), showing the current camera number and the current monitor number. Figure 55. Normal operating display CAMERA 0 MONITOR 1 A local logon feature can be set up by the installer (see System controller mode on page 48).
Iris. The iris is controlled by the + iris -key; + opens the iris and - closes the iris. Setting a preset The KTD-405 has a number of features that allow users to quickly set camera presets directly from the keypad. Installers and supervisors can also manage this capability in a flexible way.
Chapter 4 Operation that it was actually stored. If the preset number is not in the allowed range, the keypad will give an error message instead of asking for the final press of the store key. Shortcuts There are two types of shortcuts provided by the keypad for setting and recalling presets. They are useful for preset that may be changed or recalled frequently.
KTD-405/KTD-405A Controller Keypad User Manual Setting autopan limits You can set the left and right autopan limits separately. Left autopan limit To set the limit for the left turn-around point of the camera’s back and forth motion, as wells as the tilt and zoom positions for the autopan, do the following: 1.
Chapter 4 Operation Controlling a recording device When a recording device is selected, it can be controlled by the keypad. (See Table 4, Controlling a recording device Zone receiver site addressing on page 65 for details.) Table 4. Controlling a recording device Control Function for DSR/VCR Function for DVMRe...
KTD-405/KTD-405A Controller Keypad User Manual System information menus In standard Digiplex mode, holding mon at the normal operating menu displays three system information menus. These menus show the keypad’s address, version, and system size setting. Use to navigate through these menus. To exit the system information menus, press from the first menu or press esc.
Chapter 4 Operation Audio Annunciation and alarms When a keypad is programmed for site annunciation, it stacks as many as 32 call-in requests in the order in which they are received. The numbers of the first three sites appear in the keypad’s display window (Figure 60).
KTD-405/KTD-405A Controller Keypad User Manual System controller mode When the installer has set up the system in system control mode for use with the HDS switch, the keypad powers up with the login menu (Figure 61). Figure 61. System controller mode login menu...
Chapter 4 Operation Zone mode The LCD displays the zone number and title on the top line and the current camera and monitor numbers on the bottom line (Figure 62). Figure 62. Zone mode main menu ZONE -- ZONE TITLE CAMERA -- MONITOR - To select a zone, press zone and enter the zone number.
Page 54
KTD-405/KTD-405A Controller Keypad User Manual Selecting and controlling a DVMRe/multiplexer When a zone is active, the corresponding DVMRe/multiplexer can be controlled by the keypad (Table 5). Table 5. Controlling a multiplexer Control Function for multiplexer Function for DVMRe starts record mode...
Page 55
Chapter 4 Operation To enter a Calibur DVMRe/multiplexer’s programming menus, do the following: 1. Enter the remote programming mode: a. Press and hold b. Press 9-5-1-seq. 2. Select 1, switcher/multiplexer. 3. Select 2, Calibur. 4. Enter the Calibur address. 5. Press 6.
KTD-405/KTD-405A Controller Keypad User Manual Programming a DVMRe/multiplexer camera sequence If you are using a Calibur DVMRe/multiplexer, set a camera sequence by doing the following: 1. Press store. Figure 63. Enter sequence menu 2. Press seq. to display the ENTER SEQUENCE menu (Figure 63).
Troubleshooting, maintenance, support This section provides information to help you diagnose and solve various problems that may arise while configuring or using your GE Security product and offers technical support contacts in case you need assistance. In this chapter: Troubleshooting your keypad .
The keypad may be positioned incorrectly on the RS-422 control line with a switcher and data merger. Refer to the keypad, switcher, and data merger installation instructions and correct wiring along RS-422 control line. With the KTD-405 keypad, the units should be in line in the following order: keypad, data merger, and switcher.
Many GE Security documents are provided as PDFs (portable document format). To read these documents, you will need Adobe Acrobat Reader, which can be downloaded free from Adobe’s website at www.adobe.com.
Page 60
KTD-405/KTD-405A Controller Keypad User Manual...
Appendix A Sample configurations and charts This appendix provides several sample configuration diagrams to help you visualize your system and also includes DIP switch aids, charts, and other helpful information. In this appendix: Sample system configurations....... . . 58 Old I/O box connections .
KTD-405/KTD-405A Controller Keypad User Manual Sample system configurations Figure 64. Typical KTD-450 Digiplex configuration EARTH GROUND EARTH GROUND RS485 RS485 RS422 IN RS422 IN RS422 OUT RS422 OUT SPEAKER SHIELD SPEAKER SHIELD SPEAKER SPEAKER Video RS-422 RS-485 Keypads (with I/O boxes)
Page 63
Appendix A Sample configurations and charts Figure 65. Typical KTD-450A Digiplex configuration Video ZONE 32 PARKING GARAGE auto CAMERA 22 MONITOR 2 focus last view zone dsr/vcr aux 1 aux 2 aux 3 aux 4 EARTH GROUND RS-422 RS485 alarm tour store find...
Page 64
KTD-405/KTD-405A Controller Keypad User Manual Figure 66. HDS hybrid configuration Crosspoint 32 EARTH GROUND EARTH GROUND RS485 RS485 RS422 IN RS422 IN RS422 OUT RS422 OUT SPEAKER SHIELD SPEAKER SHIELD SPEAKER SPEAKER ZONE 32 PARKING GARAGE auto ZONE 32 PARKING GARAGE...
Page 65
Appendix A Sample configurations and charts Figure 67. Zone configuration EARTH GROUND EARTH GROUND RS485 RS485 RS422 IN RS422 IN RS422 OUT RS422 OUT SPEAKER SHIELD SPEAKER SHIELD SPEAKER SPEAKER Video RS-422 ZONE 32 PARKING GARAGE auto ZONE 32 PARKING GARAGE focus auto CAMERA 22...
KTD-405/KTD-405A Controller Keypad User Manual Old I/O box connections Figure 68. Old I/O box connections for audio and nonaudio keypads BR G G BK Nonaudio I/O box Audio I/O box Data connections RS-485 A RS-422 out B RS-485 B RS-422 out A...
Page 67
Appendix A Sample configurations and charts Figure 69. Connecting a multiplexer or DVMRe to the old I/O box Connect PIN 3 to RS-485 A (RD) To multiplexer or DVMRe (ground at RS-422 output (to CyberDomes/PTZ mux/DVMRe) receivers Connect PIN 6 to RS-485 B (BK) Floating shield RS-422 input (if used) Connect PIN 1 to RS-485 shield...
12 VDC in (no polarity) To additional keypads or multiplexer/ RS-422 output (to CyberDomes) DVMRe (ground at mux/DVMRe) To/from KTD-405 12 VDC in (no polarity) Figure 71. KTD-405 to KTD-405A connections BR G G BK Audio connections Shield (float) RS-422 input (from alarm chassis)
Appendix A Sample configurations and charts Zone receiver site addressing Each receiver has a DIP switch used to assign its site address. In zone operation, to determine the receiver site address, see Table 8, Table 9, and Figure 72 on page 65 and perform the following: 1.
Page 70
KTD-405/KTD-405A Controller Keypad User Manual Table 9. Receiver site addressing values by zone Zone number Camera input...
Appendix A Sample configurations and charts Reprogrammable keys and commands From the supervisor programming mode you can reprogram any of the soft keys with any of the available commands. Note: Holding the seq key for three seconds returns you to the normal operating display, except on displays where esc is required to exit.
Page 72
KTD-405/KTD-405A Controller Keypad User Manual Table 10. Commands that can be assigned to reprogrammed keys ALARM FIND LOCK STEP FIRST MACRO STEP FWD (for future use) AUTO FCS FLIP MAGNIFY STEP REV AUTO PAN GROUP OPEN STOP RCD BADGE HOME...