Outdoor Units - Mitsubishi Electric FDT125VNVF Technical Manual

Table of Contents

Advertisement

POWER SOURCE 1∼220ー240V 50Hz/1∼220V 60Hz
TB
F(30A)
F(8A)
L1i
RD
L1
1
WH
NOISE FILTER
N
Ni
2
E
GN
PWB3
E1
GN
L1o
No
GN
CT
DM
+
-
P1
N1
INVERTER
CNI2
PWB2
(WH)
I P M
CNI4
(WH)
CNACT1
U
V
W
P2
N2
(WH)
P
N2
V
W
+
-
U
MS
P
A/F MODULE
3∼
+
N2
L1
L2
CM
L
Power cable, indoor-outdoor connecting wires
MAX over current
Power cable size
Model
(A)
(mm )
2
100
125
24
5.5
140
※At the connection with the duct type indoor unit.
MAX over current
Model
Power cable size
(A)
(mm )
2
100
25
5.5
125
27
140
28
8
The specifications shown in the above table are for units without heaters. For units with heaters, refer
to the installation instructions or the construction instructions of the indoor unit.
Switchgear of Circuit breaker capacity which is calculated from MAX. over current should be chosen
along the regulations in each country.
The cable specifications are based on the assumption that a metal or plastic conduit is used with no
more than three cables contained in a conduit and a voltage drop is 2%. For an installation falling
outside of these conditions, please follow the internal cabling regulations. Adapt it to the regulation
in effect in each country.
TB
RD
1
WH
TO INDOOR UNIT
2
3
POWER WIRES
1
2
SIGNAL WIRE
3
5 or 6 wires
SM1
M
6
5
4 3
2
1
CNW
CNW2
CNEEV1
(OR)
(BK)
(WH)
BL
CNI1
(WH)
CONTROL
BL
CNI3
PWB1
(WH)
52X1
52X3
LED1
RD
CNA2
BL
(WH)
RD
CNA1
CNR
CNS
CNH
CNTH
BL
(WH)
(WH)
(RD)
(BR)
(WH)
CH
20S
63H1
THo-R1
THo-D
THo-S
Power cable length
indoor-outdoor
Earth wire size
(m)
wire size x number
(mm)
φ 1.6mm x 3
φ 1.6
25
Power cable length
indoor-outdoor
Earth wire size
(m)
wire size x number
(mm)
24
φ 1.6mm x 3
φ 1.6
22
32
5 or 6 wires
SM2
FMO1
M
M
6
5
4
3
2
1
7
6
5 4 1
CNEEV2
CNFAN1
(RD)
(WH)
Mark
ON
ON
OFF
OFF
1
2
3
4
1 2
3
4
BK
LED2
SW1
SW3
SW5
BL
BR
CNPS
CNB
GN
CNIP
(Y)
(WH)
(RD)
GR
P
OR
LPT
RD
THo-A
THo-IPM
THo-R2
WH
Y
Y/GN
Local setting switch SW3(Set up at shipment OFF)
Defrost control change
SW3-1
SW3-2
Snow guard fan control
SW3-3,4
Trial operation
Item
Description
CnA∼Z
Connector
CH
Crankcase heater
CM
Compressor motor
CT
Current sensor
DM
Diode module
F
Fuse
FM01
Fan motor
IPM
Intelligent power module
L
Reactor
LED1
Indication lamp(GREEN)
LED2
Indication lamp(RED)
LPT
Low pressure sensor
SM1
Expansion valve for cooling
Color
SM2
Expansion valve for heating
Black
SW1
Pump down switch
Blue
SW3,5
Local setting switch
Brown
TB
Terminal block
Green
THo-A
Thermistor(Outdoor air temp.)
Gray
THo-D
Thermistor(Discharge pipe temp.)
Pink
THo-IPM
Thermistor(IPM)
Orange
Thermistor(Heat exchanger pipe temp. )
THo-R1,2
Red
THo-S
Thermistor(Suction pipe temp.)
White
20S
Solenoid valve for 4 way valve
Yellow
52X1
Auxilliary relay(for CH)
Yellow/Green
52X3
Auxilliary relay(for 20S)
63H1
High pressure switch
The defrosting operation interval becomes shorter
by turning ON this switch. This switch should be
turned ON in the area where outside temperature
becomes below the freezing point.
When this switch is turned ON, the outdoor unit
fan will run for 30 seconds in every 10 minutes,
when outdoor temperature falls to 3 C or lower and
the compressor is not runnning when the unit is used
in a very snowy country, set this switch to ON.
Method of trial operation
1
Trial operation can be performed by using SW3-3,4.
2
Compressor will be in the operation when
SW3-3 is ON.
3
Cooling trial operation will be performed when
SW3-4 is OFF, and heating trial operation when
SW3-4 is ON.
4
Be sure to turn OFF SW3-3 after the trial operation
is finished.