Mitsubishi Electric FDT125VNVF Technical Manual page 76

Table of Contents

Advertisement

Model
Item
Power source
Operation data
Nominal capacity
kW
Power consumption
kW
Running current
Power factor
%
Inrush current
Sound Pressure Level
dB(A)
Exterior dimensions
mm
Height x Width x Depth
Exterior appearance
(Munsell color)
Net weight
kg
Refrigerant equipment
Compressor type & Q'ty
Starting method
Refrigerant oil
Heat exchanger
Refrigerant control
Air handling equipment
Fan type & Q'ty
Motor <Starting method>
Air flow (Standard)
CMM
External static pressure
Pa
Outdoor air intake
Air filter, Q'ty
Shock & vibration absorber
Insulation (noise & heat)
Electric heater
Remote controller
Room temperature control
Safety equipment
Installation data
mm
Refrigerant piping size
Connecting method
Refrigerant line (one way) length
Vertical height difference between
outdoor unit and indoor unit
Refrigerant Quantity
Drain pump
Drain
Insulation for piping
IP code
Standard Accessories
Notes (1) The data are measured at the following conditions.
Item
Indoor air temperature
Operation
Cooling
27˚C
Heating
(2) This packaged air-conditioner is manufactured and tested in conformity with the ISO.
(3) Sound pressure level indicates the value in an anechoic chamber. During operation these value are somewhat higher due to
ambient temperature.
(4) The operation data indicates when the air-conditioner is operated at 400V50Hz or 380V60Hz.
(5) Indoor unit specifications for one unit. Capacity and operation data is three indoor units are combined and run together.
(6) Branching pipe set "DIS-TA1"×1(option). ① : Pipe of O/U~Branch, ② : Pipe of Branch~I/U
(7) Static pressure of optional air filter "UM-FL1EF" is 5Pa initially.
(8) If wireless remote controller is used, only 3-speed fan setting (Hi-Me-Lo) is available.
Indoor unit FDUM50VF (3 units)
Cooling
14.0 [ 5.0 (Min.)~14.5 (Max.)]
4.65
A
6.9 / 7.3
A
P-Hi : 37 Hi : 32 Me : 29 Lo : 26
280 × 750 × 635
Louver fin & inner grooved tubing
Centrifugal fan × 1
W
100 < Direct line start >
P-Hi : 13 Hi : 10 Me : 9 Lo : 8
Standard : 35 Max : 100
possible
Procure locally
Rubber sleeve (for fan motor)
Polyurethane form
W
Thermostat by electronics
Overload protection for fan motor
Frost protection thermostat
Liquid line : I/Uφ6.35 (1/4") ②φ9.52 (3/8") × 0.8 ①φ9.52 (3/8") × 0.8
: I/Uφ12.7 (1/2") ②φ12.7 (1/2") × 0.8 ①φ15.88 (5/8") × 1.0 O/Uφ15.88 (5/8")
Gas line
Flare piping
Max.30m (Outdoor unit is higher)
Max.15m (Outdoor unit is lower)
R410A 3.8kg in outdoor unit (incl. the amount for the piping of : 30m)
Built-in Drain pump
Hose Connectable with VP20
IPXO
Drain hose
Outdoor air temperature
BD
WB
DB
19˚C
35˚C
20˚C
7˚C
FDUM140VSTVF
97
5 < Max.running current 15 >
29
wired : RC-E5 (option) wireless : RCN-KIT3-E (option)
Max.50m
Necessary (both Liquid & Gas lines)
External static pressure of indoor unit
WB
24˚C
6˚C
75
-
-
'12 • PAC-T-174
Adapted to RoHS directive
Outdoor unit FDC140VS
380-415V 3N~50Hz / 380V 3N~60Hz
Heating
16.0 [ 4.0 (Min.)~16.5 (Max.)]
5.15
7.7 / 8.1
97
51
845 × 970 × 370
Stucco White
(4.2Y7.5/1.1) near equivalent
83
RMT5126MDE3 × 1
Direct line start
0.9 M-MA68
M shape fin & inner grooved tubing
Electronic expansion valve
Propeller fan × 1
86 < Direct line start >
Cooling : 75 , Heating : 73
0
Rubber sleeve (for Compressor)
20 (Crank case heater)
Internal thermostat for fan motor
Abnormal discharge temperature protection.
O/Uφ9.52 (3/8")
Flare piping
See page 155
Holes size φ20 × 3pcs
IPX4
Edging
Pa
60
PJG000Z032