1.10.3 Installation of wired remote controller (option)
Installation manual for wired remote controller
(1) Model RC-E5
Read together with indoor unit's installation manual.
Fasten the wiring to the terminal securely and hold the cable securely so as not to apply unexpected stress on the
terminal.
Loose connection or hold will cause abnormal heat generation or fire.
Make sure the power supply is turned off when electric wiring work.
Otherwise, electric shock, malfunction and improper running may occur.
DO NOT install the remote controller at the following places in order to avoid malfunction.
(1) Places exposed to direct sunlight
(2) Places near heat devices
(3) High humidity places
DO NOT leave the remote controller without the upper case.
In case the upper cace needs to be detached, protect the remote controller with a packaging box or bag in
order to keep it away from water and dust.
Accessories
Prepare on site
Installation procedure
Open the cover of remote controller , and remove the screw under the
buttons without fail.
Remove the upper case of remote controller.
Insert a flat-blade screwdriver into the dented part of the upper part
of the remote controller, and wrench slightly.
[In case of embedding cord]
Embed the erectrical box and remote controller cord beforehand.
Prepare two M4 screws (recommended length is 12-16mm) on site, and install the lower case to erectrical box.
Choose either of the following two positions in fixing it with screws.
Wiring oulet
Connect the remote controller cord to the terminal block.
Connect the terminal of remote controller (X,Y) with the terminal of
indoor unit (X,Y). (X and Y are no polarity)
Install the upper case as before so as not to catch up the remote controller cord,
and tighten with the screws.
[In case of exposing cord]
You can pull out the remote controller cord from left upper part or center upper part.
Cut off the upper thin part of remote controller lower case with a nipper or knife,
and grind burrs with a file etc.
Install the lower case to the flat wall with attached two wooden screws.
WARNING
CAUTION
(4) Hot surface or cold surface enough to generate condensation
(5) Places exposed to oil mist or steam directly
(6) Uneven surface
Remote controller, wood screw (ø3.5 16) 2 pieces
Remote controller cord (2 cores) the insulation thickness in 1mm or more.
[In case of embedding cord] Erectrical box, M4 screw (2 pieces)
[In case of exposing cord] Cord clamp (if needed)
Upper part
Lower case
Lower part
259
-
Screw
Controller cord
Upper part
Tighten the screws after
cutting off the thin part of
screw mounting part.
Lower case
Lower part
Wiring oulet
M4 screw
The thin part
-
'12 • PAC-T-174
Connect the remote controller co
PJA012D730
terminal block.
Connect the terminal of remote
with the terminal of indoor unit (X
(X and Y are no polarity)
Wiring route is as shown in the r
depending on the pulling out dire
The wiring inside the remote con
The sheath should be peeled of
The peeling-off length of each w
Pulling out from upper left Pul
Install the upper case as before
the screws.
In case of exposing cord, fix the
Installation and wiring of remote c
Wiring of remote controller shou
Maximum prolongation of remot
If the prolongation is over 100m
But, wiring in the remote control
of the case according to wire co
connecting section. Be careful a
100 - 200m ......................... 0.5m
Under 300m ....................... 0.75m
Under 400m ....................... 1.25m
Under 500m ....................... 2.0m
Master/ slave setting when more th
A maximum of two remote controllers
Erectrical box
(Prepare on site)
Remote controller
SW1 "Master"
Set SW1 to "Slave" for the slave r
Note: The setting "Remote controller
controller in the position where
The air conditioner operation fo
master/ slave setting of it.
The indication when power source
When power source is turned on, the
communication between the remote c
Master remote controller : "
2 (Prepare on site)
Slave remote controller : "
At the same time, a mark or a numbe
Upper
This is the software's administration n
Lower case
Lower
When remote controller cannot comm
Upper
appear.
Check wiring of the indoor unit and th
Lower case
Lower
X wiring : 215mm
Y wiring : 195mm
Indoor units
Remote contro
Remote controller
SW1 "Slave"