groupAssignErr
-10413
reservedPinErr
-10414
DSPDataPathBusyError
-10416
SCXIModuleNotSupportedErr
-10417
or
chassisSynchedError
-10344
chassisMemAllocError
-10345
badPacketError
-10346
chassisCommunicationError
-10347
waitingForReprogError
-10348
SCXIModuleTypeConflictErr
-10349
or
sysOwnedRsrcErr
-10440
group.
A group is already assigned, or the
specified line or channel is already
assigned to a group.
The selected signal requires a pin that is
reserved and configured only by
NI-DAQ. You cannot configure this pin
yourself.
Either DAQ or WFM can use a PC
memory buffer, but not both at the same
time.
At least one of the SCXI modules
specified is not supported for the
operation.
The Remote SCXI unit is not
synchronized with the host. Reset the
chassis again to resynchronize it with the
host.
The required amount of memory cannot
be allocated on the Remote SCXI unit for
the specified operation.
The packet received by the Remote SCXI
unit is invalid. Check your serial port
cable connections.
There was an error in sending a packet to
the remote chassis. Check your serial
port cable connections.
The Remote SCXI unit is in
reprogramming mode and is waiting for
reprogramming commands from the host
(NI-DAQ Configuration Utility).
The module ID read from the SCXI
module conflicts with the configured
module type.
The specified resource is owned by the
driver and cannot be accessed or
modified by the user.