4.6 Replacing the Management Blade

In this chassis two Management Blades are installed by default and the management
/monitoring function is redundant.
It is necessary to replace a broken Management Blade. Contact an office listed in the
"Contact Information" of "Start Guide".
If one Management Blade fails, it is possible to replace the Management Blade without turning off the
main power supply of the chassis or the server blade (hot-swap/hot-plug responsive). Check the slot
position of the failed Management Blade using the Management Blade error LED or ServerView.
For details about Management Blade, refer to "BX600 Management Blade Hardware Guide".
■ Management Blade slot
Management Blades are installed to all the slots by default.
[Rear of the chassis]
Management Blade
slot 2
Always use the same Management Blade firmware version (except for when updating firmware).
Have broken PSUs replaced as soon as possible.
PRIMERGY BX600 S2 Blade Server System Unit Hardware Guide
Management Blade
slot 1