Note: The default setting of SS is 03, which means once an object is detected more than 3 grids, the
system will get triggered. So the value of SS must be less than the number of grids that you set
up for the motion detection area.
3)
TS (Time of Sensitivity)
"TS" is to set the sensitivity regarding how long one object stays in the detection area and triggers the
recording. The smaller the value is, the higher sensitivity for motion detection.
The highest sensitivity setting is 00, and the lowest sensitivity setting is 15. The default setting is 02.
4)
MOTION
Select if you want to activate the motion detection function for the selected channel (ON/OFF).
5)
ALARM
Select N.C./ N.O depending on your installation need. The default alarm value is OFF.
6)
AREA
Click "EDIT" to set the motion detection area.
There are 16 × 12 grids per camera for all channels. Pink blocks represent the area that is not being
detected while the transparent blocks are the area under detection.

5.5.3 ALERT

CANERA
DETECTION
ALERT
NETWORK
DISPLAY
RECORD
DEVICES
DCCS
IVS
NOTIFY
EXIT
1)
EXT. ALERT
Select to enable or disable the sound when any external alarm is triggered (ON / OFF).
2)
INT. BUZZER
Select to enable or disable the sound (ON / OFF) for all internal buzzers: KEY BUZZER, VLOSS BUZZER,
MOTION BUZZER, ALARM BUZZER, and HDD BUZZER.
Note: When this item is set to "OFF", item 3) to item 7) will be disabled even though they are set to ON.
3)
KEY BUZZER
Select to enable or disable the sound when pressing the buttons on the front panel (ON / OFF).
4)
VLOSS BUZZER
Select to enable or disable the sound when video loss happened (ON / OFF).
5)
MOTION BUZZER
Select to enable or disable the sound when any motion alarm is triggered (ON / OFF).
6)
ALARM BUZZER
Select to enable or disable the sound when any internal alarm is triggered (ON / OFF).
7)
HDD BUZZER
Select to enable or disable the sound (ON / OFF) when the HDD remaining capacity reaches to the value set
in "HDD NEARLY FULL (GB)".
ADVANCED CONFIG
EXT. ALERT
INT. BUZZER
KEY BUZZER
VLOSS BUZZER
MOTION BUZZER
ALARM BUZZER
HDD BUZZER
ALARM DURATION (SEC)
HDD NEARLY FULL (GB)
ON
OFF
ON
ON
ON
ON
ON
5
5
22