Alarm Setup - Bosch VEZ-400 Series Operation Manual

Autodome 4000 mini ptz dome
Hide thumbs Also See for VEZ-400 Series:
Table of Contents

Advertisement

AUTODOME 4000 Mini PTZ Dome
2.
3.
4.
5.
6.
7.
8.
9.
10. Select the option "Speed."
11. Select the desired speed (from 1° to 35°/second).
12. Select the option "DTime" to set the dwell time for the scan.
13. Set the desired time (from 3 minute to 60 seconds).
14. Select the option "Direction."
15. Select the appropriate value for the direction of the scan.
16. Select the option "Mode."
17. Select the appropriate value for the mode. In Auto Scan there are two modes:
18. Save the settings.
Notice!
In order to call an action (Preset, Pattern, Tour, or Scan), you must save Preset, Pattern,
Tour, or Scan first.
You can also edit the Scan title. Select the option "Title," then edit the title following the
steps in Editing Titles, page 46.
10.11

Alarm Setup

This menu controls alarm inputs and outputs. To set alarms:
1.
2.
ALARM SETUP
NO.
IN
OUT
PRIORITY
ACTION
NUMBER
Bosch Security Systems, Inc.
Select the appropriate scan number.
Select the option "Edit."
Select the value "Edit Start Point." The screen Start Position Setup appears.
Using the joystick, move to a desired target (Pan/Tilt/Zoom) for the starting point of the
scan.
Save the settings. The screen Stop Position Setup appears.
Using the joystick, move to a desired target (Pan/Tilt/Zoom) for the stopping point of the
scan.
Save the settings.
Return to the previous screen.
Endless mode: When the Start Position is the same as the Stop Position, the dome
moves around.
Coming/Going mode: When the Start Position is different from the Stop Position, the
dome moves repeatedly from one position to another.
Note: Select the option "Clear" to delete the scan.
From the MAIN MENU, select ALARM SETUP. The screen ALARM SETUP appears.
Select the option "NO.###" to select a preset number.