Alarm I/O Setup - Bosch series VG4-300 User Manual

Autodome modular camera system
Hide thumbs Also See for series VG4-300:
Table of Contents

Advertisement

16
en | On-Screen Display Menu Navigation
2.7

Alarm I/O Setup

The Alarm Setup Menu provides access to the Alarm I/O Setup Menu to establish the alarm
inputs and outputs and to configure alarm rules.
Exit...
Inputs Setup...
Outputs Setup...
Rule Setup...
Restore Defaults...
Alarm Setup Menu Choices:
Menu
Exit
Inputs Setup
Inputs 1-7
Inputs 8-12
NOTICE! Alarm inputs 1 and 2 provide tamper detection, if programmed as supervised, for
i
breaks or shorts in an alarm circuit. See the AutoDome Modular Camera System Installation
Manual for wiring instructions.
F01U064036 | 1.1 | 2007.01
Alarm I/O Setup
Focus / Iris: Select
Description
Saves and exits the menu.
Defines physical inputs or events and
commands that can be used in a rule.
There are twelve (12) alarm inputs
available.
Defines the type of physical input.
Defines input commands that can be
used in a rule. Command inputs can
also be customized by using non-
assigned keyboard command num-
bers.
VG4-200, VG4-300, VG4-500i Series User's Manual
Inputs Setup
Exit...
1. Alarm Input 1
N.C.S.
2. Alarm Input 2
N.O.S.
3. Alarm Input 3
N.O.
4. Alarm Input 4
N.C.
5. Alarm Input 5
N.O.
6. Alarm Input 6
N.C.
7. Alarm Input 7
N.O.
8. NONE
9. NONE
10. NONE
11. NONE
12. NONE
Focus / Iris: Select Type
Right / Left: Select Mode
Sub-menu / Description
N.O.: Normally open dry contact.
N.C.: Normally closed dry contact.
N.C.S.: Normally closed supervised contact.
N.O.S.: Normally open supervised contact.
NONE: No command defined.
Aux On: Programs a standard or custom key-
board ON (1-99) command.
Aux Off: Programs a standard or custom
keyboard OFF (1-99) command.
Shot: Programs a Preset shot or scene from
1-99. (200 Series 1-64).
AutoTrack: Triggers an alarm when set to
ON. (Available with 500i Series only).
Motion Detection: Triggers an alarm when
set to ON. (Available with 500i Series only).
AutoDome Modular Camera System
1-7
Physical
Inputs
8-12
Command
Inputs
Default
Setting
N.O.
NONE
Bosch Security Systems, Inc.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vg4-200 seriesVg4-500i series

Table of Contents