MTU 16V4000Lx2x Operating Instructions Manual page 92

Table of Contents

Advertisement

1.4540.036 – FGP High Limit Error
Red alarm. Initiated by TecJet.
Cause
Hardware not ready for
operation.
1.4540.037 – Watchdog Reset
Red alarm. Initiated by TecJet.
Cause
Hardware not ready for
operation.
1.4540.038 – CAN Flow Demand Failed
Red alarm. Initiated by TecJet.
Cause
TecJet setting is not correct.
1.4540.040 – TecJet Shutdown
Red alarm. Initiated by TecJet.
Cause
TecJet combined alarm. At least
one further TecJet alarm is
present.
1.4540.041 – TecJet Internal Fault
Red alarm. Initiated by TecJet.
Cause
Hardware not ready for
operation.
1.4540.042 – Keyswitch State
Red alarm. Initiated by TecJet.
Cause
Keyswitch cabling missing.
1.4540.043 – Parameter Error
Red alarm. Initiated by TecJet.
Cause
Hardware not ready for
operation.
92 | Troubleshooting | MS150121/00E 2015-07
Corrective action
u Restart TecJet.
Corrective action
u Restart TecJet.
Corrective action
u Check setting.
Corrective action
u Rectify cause of alarm.
Corrective action
u Restart TecJet.
Corrective action
u Check cabling.
Corrective action
u Restart TecJet.