Number of cylinders
Coolant pump: Volumetric flow
Pressure in cooling system, max.
Pressure loss over mixture cooler (at nominal flow rate 8.56)
Table 25: Coolant system (LT circuit, referenced to max. power without HT heat extraction)
Lube oil system (referenced to max. power without HT heat extraction)
Number of cylinders
Lube oil operating temperature after oil heat exchanger, from
Lube oil operating temperature after oil heat exchanger, to
Lube oil operating temperature after oil heat exchanger, warning
Lube oil operating temperature after oil heat exchanger, engine shutdown
Lube oil pressure after oil filter
Lube oil pressure after oil filter, warning
Lube oil pressure after oil filter, shutdown
Table 26: Lube oil system (referenced to max. power without HT heat extraction)
Fuel system
Number of cylinders
Gas temperature before engine, min.
Gas temperature before engine, max.
Gas flow pressure before Tecjet, min.
Gas flow pressure before Tecjet, max.
Table 27: Fuel system
General operating data
Number of cylinders
Cold start capability: Air temperature (w/o starting aid, with preheating) -
(case C)
Site condition (to case C): Engine coolant temperature
32 | Product Summary | MS150121/00E 2015-07
A
m³/h
L
bar
bar
R
°C
R
°C
R
°C
L
°C
bar
bar
L
bar
L
°C
See MTU
Fluids and
Lubricants
Specifica-
tions
L
°C
See MTU
Fluids and
Lubricants
Specifica-
tions
L
mbar
See MTU
Fluids and
Lubricants
Specifica-
tions
L
mbar
See MTU
Fluids and
Lubricants
Specifica-
tions
R
°C
R
°C
16
27
6.0
0.4
16
82
90
93
97
5.5
4.5
4.0
16
16
15
40