1.4540.029 – Battery Volt Low Error
Red alarm. Initiated by TecJet.
Cause
Supply voltage has reached
minimum limit value.
1.4540.030 – FGT Low Limit Error
Red alarm. Initiated by TecJet.
Cause
Hardware not ready for
operation.
1.4540.031 – Delta P Low Limit Error
Red alarm. Initiated by TecJet.
Cause
Hardware not ready for
operation.
1.4540.032 – FGP Low Limit Error
Red alarm. Initiated by TecJet.
Cause
Configured limit value was not
attained.
1.4540.033 – Battery Volt High Error
Red alarm. Initiated by TecJet.
Cause
Supply voltage has reached
maximum limit value.
1.4540.034 – FGT High Limit Error
Red alarm. Initiated by TecJet.
Cause
Hardware not ready for
operation.
1.4540.035 – Delta P High Limit Error
Red alarm. Initiated by TecJet.
Cause
Hardware not ready for
operation.
Corrective action
1. Check supply voltage.
2. Check cabling.
Corrective action
u Restart TecJet.
Corrective action
u Restart TecJet.
Corrective action
u Check position direction of TecJet.
Corrective action
1. Check supply voltage.
2. Check cabling.
Corrective action
u Restart TecJet.
Corrective action
u Restart TecJet.
MS150121/00E 2015-07 | Troubleshooting | 91